根据"通用标准",是否接受先前经过验证的血压自测设备? 一个系统的审查
Estefanie Siqueira Vigato de Oliveira1, Nila Larisse Silva de Albuquerque, Priscila Rangel Dordetto
1School of Nursing - University of Campinas (UNICAMP), Campinas, São Paulo, Brazil.
Journal of hypertension
|October 1, 2024
概括
大多数振荡计血压仪满足了最初的通用标准标准,但只有53%完全满足了自测验证的所有要求. 这影响了获得批准的家庭血压监测设备的可用性.
科学领域:
- 心血管诊断心血管诊断
- 医疗器械监管法规 医疗器械监管法规
- 高血压管理 高血压管理
背景情况:
- 精确的血压自测对于管理高血压至关重要.
- 对于振荡计设备的现有验证协议有所不同,可能会影响设备的批准.
- 该通用标准提供了验证血压监测设备的标准.
结论:
- 验证协议的显著差异导致分析的设备中只有53%符合通用标准的标准.
- 这项研究扩大了在通用标准下验证的自我测量设备的池.
- 需要在验证研究中进一步标准化,以确保可靠的家庭血压监测设备.
相关概念视频
Assessment of blood pressure in brachial artery(one-step method)
556
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
556
Equipments Used To Measure Blood Pressure
838
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
838
Errors occurring during blood pressure monitoring
607
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
607
Assessment of blood pressure in brachial artery(two-step method)
659
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
659
Sites for measruring blood pressure
1.5K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.5K
Special considerations while measuring blood pressure
708
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
708