基于负载预测对企业的变压器过载和新能源规划的识别
1School of Finance and Information, Ningbo University of Finance and Economics, Ningbo, China.
PloS one
|October 2, 2024
概括
这项研究优化了面临变压器过载的企业的新能源系统. 它提出了一个负载预测和光伏 (PV) 和储能系统的最佳配置模型,以减少电力成本和排放.
科学领域:
- 电气工程 电气工程
- 能源系统 能源系统
- 运营研究 运营研究
背景情况:
- 变压器过载是许多企业面临的重大运营挑战.
- 整合新的能源系统,包括光伏发电和储能,为变压器过载,成本降低和低碳排放减少提供了解决方案.
- 投资回报率低,目前阻碍企业采用新能源系统.
研究的目的:
- 为潜在的客户开发光伏和储能系统的最佳配置模型,以应对变压器过载的情况.
- 建立负载预测模型,以确定有新能源安装需求的潜在客户.
- 确定最佳的光伏装机容量和储能充/放电策略,以降低电力成本并确保运营能力.
主要方法:
- 为潜在客户开发负载预测模型.
- 基于非线性编程的光伏和储能系统的最佳配置模型.
- 一个建筑材料生产工厂的案例研究分析.
主要成果:
- 通过负载预测识别潜在客户.
- 确定最佳的光伏和储能能力和运营策略.
- 通过案例研究来证明降低成本和提高效率.
结论:
- 建议的优化策略有效地解决了企业的变压器过载问题.
- 光伏和储能系统的最佳配置带来了显著的经济效益和减排.
- 开发的模型为在工业环境中实施新能源解决方案提供了实际框架.
更多相关视频
相关概念视频
Transformers in Distribution System
99
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
99
Energy Losses in Transformers
841
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
841
Reducing Line Loss
149
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
149
Instrument Transformers
76
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
76
Types Of Transformers
951
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
951
Equivalent Circuits for Practical Transformers
399
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
399