使用刺激拉曼散射显微镜进行皮肤透通路的表征
Anukrati Goel1, Ruth Pendlington2, Stephen Glavin2
1School of Chemistry and Chemical Engineering, University of Surrey, Guildford GU2 7XH, UK.
概括
这项研究揭示了分子脂性如何决定局部透到皮肤层. 水友性物质有利于角质细胞,而脂友性物质则更喜欢细胞间脂质矩阵,以有效地进行局部输送.
科学领域:
- 皮肤病学 皮肤病学
- 材料科学 材料科学 材料科学
- 生物物理学的生物物理.
背景情况:
- 了解皮肤透对于局部药物输送和护肤至关重要.
- 皮肤的复杂结构对有效的局部产品配方构成障碍.
研究的目的:
- 为了研究人类皮肤内的模型透剂的分区行为.
- 阐明分子性质和皮肤透途径之间的关系.
主要方法:
- 使用刺激拉曼散射 (SRS) 显微镜进行无标签的化学成像.
- 评估了六种具有不同脂友性 (logP值) 的模型透物的分区.
- 分析了通过细胞间脂质基质和细胞内角质细胞路径的透.
主要成果:
- 分子脂性强烈影响分裂成皮肤.
- 脂性化合物优先分离到细胞间脂质基质中.
- 水友分子对角细胞细胞的亲和力增加.
结论:
- 这些发现澄清了基于脂友性 (lipophilicity) 的局部物质透机制.
- 为开发更安全,更有效的局部药物和护肤提供了洞察力.
- 提供先进的成像方法,以评估健康和患病皮肤的药物输送.
相关概念视频
Raman Spectroscopy: Overview
2.6K
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
2.6K
Raman Spectroscopy Instrumentation: Overview
1.8K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.8K