智能手表的准确性用于远程评估运动能力
Alexandra Jamieson1, Siana Jones2, Nishi Chaturvedi2
1MRC Unit for Lifelong Health and Ageing, UCL, 5th Floor, 1-19 Torrington Place, London, WC1E 7HB, UK. alexandra.jamieson@ucl.ac.uk.
Scientific reports
|October 3, 2024
概括
消费者智能手表在6分钟步行测试 (6MWT) 等标准化测试中准确测量运动能力. 这项技术可以实现远程,无监督的运动测试,改善患者护理和监测心血管健康.
科学领域:
- 心血管生理学心血管生理学
- 可穿戴技术可穿戴技术
- 远程健康监测 远程健康监测
背景情况:
- 运动能力是死亡率的一个关键预测因素.
- 标准化测试 (6MWT,3MST,10CRT) 评估运动能力,但需要亲自监测.
- 消费者智能手表提供了远程监控这些测试的潜力.
研究的目的:
- 评估消费级智能手表在标准化测试中测量运动能力的准确性.
- 开发使用智能手表进行远程,无监督的运动测试的框架.
主要方法:
- 16名健康成年人进行了6次MWT (标准和连续圈),3次MST和10次CRT.
- 参与者佩戴的是加敏Vivoactive4和Fitbit Sense智能手表.
- 智能手表数据 (距离,步数,心率) 与参考指标 (计轮,计数器,心电图) 进行了比较.
主要成果:
- 连续圈6MWT显示出两个设备的距离精度比标准6MWT更好.
- 加敏智能手表在步数上比Fitbits更准确.
- 这两种设备都准确地测量了休息和恢复心率 (≤3%),在运动高峰时的精度下降 (~7-12%).
结论:
- 消费者智能手表可以准确地测量年轻人的运动能力.
- 标准化测试与智能手表相结合,可实现可靠的远程,无监督的运动能力评估.
- 这种方法可以增强患者护理和心血管健康监测.
相关概念视频
Exercise Stress Test
177
Introduction
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
177
Holter Monitor: 24-Hour Monitoring
3
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
3
Pulse rhythm
769
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
769
Electrocardiogram
2.2K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.2K
Equipments Used To Measure Blood Pressure
838
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
838
Assessment of blood pressure in brachial artery(two-step method)
659
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
659