在不同的分析平台上对34种临床化学分析物的细菌干扰:依赖于方法或分析器?
Alen Vrtaric1, Marijana Miler1, Nora Nikolac Gabaj2
1Working Group for Preanalytical Phase of the Croatian Society of Medical Biochemistry and Laboratory Medicine, Zagreb, Croatia; Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia.
Clinica chimica acta; international journal of clinical chemistry
|October 10, 2024
概括
临床化学测试中的菌干扰因分析平台和方法而异. 一些干扰,如影响甘油三,胆固醇和尿酸的干扰,对分析仪中的胆红素度更敏感.
科学领域:
- 临床化学 临床化学
- 实验室医学 实验室医学
- 分析毒理学分析毒理学
背景情况:
- 胆红素是血代谢的常见副产品,可以干扰实验室检测.
- 在临床化学中,以升高的胆红素水平为特征的菌体构成了诊断挑战.
- 了解干扰模式对于准确的患者结果至关重要.
研究的目的:
- 评估增加胆红素度对34种临床化学分析物的影响.
- 为了确定干扰是否依赖于使用的分析平台和方法.
- 为了比较四个不同的分析平台的干扰模式.
主要方法:
- 一个聚合的血清样本被添加了胆红素,以创建黄色样本.
- 在四个分析平台上对34种分析物的测量进行了重复测量.
- 偏差是根据非黄色样本计算的,并与外部质量保证标准进行比较.
主要成果:
- 大多数分析结果显示,疹的干扰最小.
- 甘油三,胆固醇和尿酸对胆红素干扰的敏感性最高.
- 干扰模式在不同的分析平台上有很大差异.
结论:
- 在所有临床化学测定中,Icterus干扰并不均.
- 在干扰中观察到分析器特定的差异,即使使用相同的分析方法.
- 方法和分析器的选择是缓解黄干扰的关键因素.
更多相关视频
相关概念视频
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
407
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
407
Ion-Exchange Chromatography
382
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
382
Enzyme-Linked Immunosorbent Assay
12.5K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
12.5K