在可见波段的偏光谱双向反射率分布函数基于考契的实证分散方程
Zhiyong Yang1, Xiaowei Wang2, Zhiwei Zhang1
1State Key Discipline Laboratory of Ordnance Launch Theory and Technology, Rocket Force Engineering University, Xi'an, 710025, China.
Scientific reports
|October 10, 2024
概括
一个新的极化光谱双向反射分布函数 (pSBRDF) 模型准确地描述了光谱极化特征. 该模型增强了对光极化如何随波长和角度变化而改变涂层面料的理解.
科学领域:
- 光学和光子学 在光学和光子学.
- 材料科学 材料科学 材料科学
- 遥感 遥感 遥感 遥感
背景情况:
- 极化双向反射分布函数 (pBRDF) 在单个波长上模拟现有的极化特征.
- 在描述目标的两极分化的光谱特征方面存在差距.
- 需要进一步的研究来建模波长依赖的极化.
研究的目的:
- 提出一个修改的三组分极化光谱双向反射分布函数 (pSBRDF).
- 为了将波长依赖性纳入偏振建模.
- 准确描述极化特征的光谱和空间分布.
主要方法:
- 开发了一种经过修改的pSBRDF模型,结合了弗雷内尔方程和考奇的实证分散方程.
- 引入了波长变量和波长独立的分散常量.
- 测量了涂层织物在光谱范围 (400-760 nm) 和不同撞击角度的线性极化度 (DoLP).
主要成果:
- 拟议的pSBRDF模型在描述光谱和空间DoLP分布方面表现出高准确性.
- 对光谱和空间DoLP的模型误差分别控制在0.00743和0.0757之间.
- 在涂层织物样本上验证了该模型的有效性.
结论:
- 开发的pSBRDF模型准确地捕捉了光谱极化特性.
- 这项研究为分析目标极化特征提供了基础模型.
- 为极化检测应用的进步提供了理论基础.
更多相关视频
07:05Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters
Published on: June 18, 2021
2.4K
08:54Performing Spectroscopy on Plasmonic Nanoparticles with Transmission-Based Nomarski-Type Differential Interference Contrast Microscopy
Published on: June 5, 2019
7.6K
相关概念视频
IR Spectrometers
1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
295
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
295
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Spectrophotometry: Introduction
3.0K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
3.0K