对网络攻击的潜在智能电网漏洞:当前的威胁和现有的缓解策略
Bishowjit Paul1, Auvizit Sarker1, Sarafat Hussain Abhi1
1Department of Mechatronics Engineering, Rajshahi University of Engineering & Technology, Rajshahi, Bangladesh.
Heliyon
|October 14, 2024
概括
智能电网 (SG) 整合了可再生能源,但由于其通信网络而面临网络安全风险. 本审查分析了SG漏洞,攻击和缓解策略,以提高安全性.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 网络安全 网络安全
背景情况:
- 智能电网 (SG) 将可再生能源整合到传统电网中.
- 总服务器利用现有的通信技术,继承它们的漏洞.
- 利用这些漏洞会带来隐私泄露,级联失败和停电等风险.
研究的目的:
- 为智能电网网络安全提供全面分析.
- 检查固有的弱点,分类常见的攻击,并评估其影响.
- 探索缓解和检测策略,以及未来的研究方向.
主要方法:
- 分析智能电网漏洞和现有的通信技术.
- 针对智能电网的网络攻击的分类.
- 对缓解和检测算法和策略的审查.
- 确定当前的研究挑战和未来的举措.
主要成果:
- 由于遗传的技术漏洞,智能电网面临着重大的网络安全挑战.
- 各种攻击媒介可能会危及SG行动,导致严重后果.
- 有效的缓解和检测策略对于强大的SG安全至关重要.
- 需要进行持续的研究,以应对不断变化的威胁并增强弹性.
结论:
- 确保智能电网的安全对于其最佳性能和可靠性至关重要.
- 需要采用结合技术解决方案和战略规划的多方面的方法.
- 解决漏洞和网络安全之间的复杂关系是强有力的防御的关键.
- 未来的举措应侧重于积极的威胁检测和弹性系统设计.
相关概念视频
Zones of Protection
146
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
146
Line Protection with Impedance Relays
68
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
68
Pilot and Numeric Relaying
83
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
83
Power System Three-Phase Short Circuits
78
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
78
Control of Power Flow
255
There are several methods to control power flow in power systems:
255
Distribution Reliability and Automation
106
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
106