Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Design Example01:23

Design Example

317
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
317

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Correction: YTHDF2 in peritumoral hepatocytes mediates chemotherapy-induced antitumor immune responses through CX3CL1-mediated CD8<sup>+</sup> T cell recruitment.

Molecular cancer·2026
Same author

Gas flow tracking for electronic pressure control system in gas chromatography under state constraints and hysteresis:An innovative fuzzy adaptive control approach.

ISA transactions·2026
Same author

The TaERF3-<i>TaPROT2</i> Module Enhances Wheat Cadmium Tolerance.

Plants (Basel, Switzerland)·2026
Same author

Early prediction of prolonged mechanical ventilation in invasively ventilated patients with subarachnoid hemorrhage: A MIMIC-IV prediction model study.

Clinical neurology and neurosurgery·2026
Same author

Targeting N<sup>1</sup>-methyladenosine modification in osteoblasts through tRNA methyltransferase 10C reverses mitochondrial dysfunction and ameliorates osteoporosis.

Signal transduction and targeted therapy·2026
Same author

PMTNet: A Part-Centric Missing-Aware Temporal Network for Cat Behavior Recognition in Unconstrained Videos.

Animals : an open access journal from MDPI·2026

相关实验视频

Updated: Jun 10, 2025

Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance
06:26

Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance

Published on: September 27, 2024

391

一种用于便携式设备的自动咳计数方法和系统构造.

Yixuan Wang1, Kehaoyu Yang2,3, Shaofeng Xu2,3

  • 1Engineering Training Centre, Beihang University, Beijing, China.

Frontiers in bioengineering and biotechnology
|October 14, 2024
PubMed
概括
此摘要是机器生成的。

这项研究开发了一种可穿戴设备,用于自动计数咳,达到93.24%的准确性. 该系统可以长期监测咳,以改善呼吸系统疾病的管理.

关键词:
梅尔的频率是塞普斯特勒姆系数的系数.咳计数正在进行中.便携式设备 便携式设备 是一种便携式设备.短时间的特色短暂的功能.支持矢量机器的支持矢量机器

更多相关视频

Methods for Detecting Cough and Airway Inflammation in Mice
04:33

Methods for Detecting Cough and Airway Inflammation in Mice

Published on: August 2, 2024

569
A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
05:32

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device

Published on: November 24, 2016

7.9K

相关实验视频

Last Updated: Jun 10, 2025

Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance
06:26

Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance

Published on: September 27, 2024

391
Methods for Detecting Cough and Airway Inflammation in Mice
04:33

Methods for Detecting Cough and Airway Inflammation in Mice

Published on: August 2, 2024

569
A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
05:32

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device

Published on: November 24, 2016

7.9K

科学领域:

  • 生物医学工程 生物医学工程
  • 信号处理 信号处理
  • 呼吸系统医学 呼吸系统医学

背景情况:

  • 咳是呼吸系统疾病的一个关键症状.
  • 长时间的咳监测有助于临床诊断.
  • 咳频率是肺部健康的重要指标.

研究的目的:

  • 设计一个自动咳计数系统.
  • 为了使每分钟咳频率的长期监测.
  • 开发一种可穿戴设备,用于持续咳评估.

主要方法:

  • 一个咳计数系统,涉及去,分段提取,固有值计算和识别.
  • 算法基于50名患者的音频,使用短时间特征和Mel频率塞普斯特尔系数 (MFCC).
  • 开发一个带有获取和接收软件的可穿戴设备.

主要成果:

  • 获得了93.24%的准确性,97.58%的灵敏度,86.97%的特异性和94.47%的F1分数.
  • 卡帕值为0.9209,平均计数误差为每分钟0.46个计数.
  • 平均运行时间为2.80±2.27秒,证明了实时性能.

结论:

  • 该系统比现有方法提供了更好的准确性,实时性能和计算速度.
  • 这种可穿戴设备有助于长期监测患者的咳.
  • 适用于具有有限计算能力的便携式设备,用于持续健康评估.