在脉冲操作期间间接测量晶体管模具温度的热学测量
Arkadiusz Hulewicz1, Krzysztof Dziarski2, Łukasz Drużyński2
1Institute of Electrical Engineering and Electronics, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland.
Sensors (Basel, Switzerland)
|October 16, 2024
概括
这项研究使用温度计测量了碳化晶体管的温度. 研究人员发现,盒子和模块之间的最大温度差异为27.3°C,使得晶体管运行更安全,更优.
科学领域:
- 电气工程 电气工程
- 材料科学 材料科学 材料科学
- 热管理 热管理
背景情况:
- 碳化 (SiC) 晶体管,如C2M0280120D,在现代电子产品中至关重要.
- 准确的温度监测对于SiC晶体管的性能和寿命至关重要.
- 脉冲模式操作带来了独特的热挑战.
研究的目的:
- 在脉冲条件下调查C2M0280120D晶体管的间接温度测量.
- 为了确定晶体管外和模块之间的温度差异.
- 为了建立安全的操作参数和优化性能.
主要方法:
- 在脉冲模式 (1千赫至800千赫) 中对C2M0280120D晶体管进行间接温度测量.
- 使用Flir E50温度摄像头和Pt1000传感器进行温度测量.
- 通过体二极管的电压下降和模拟在Solidworks 2020中确定晶体管模块温度.
主要成果:
- 案例和结点之间的最大记录温度差异为27.3°C.
- 热成像为温度评估提供了一种安全的方法,避免了电击风险.
- 模拟结果与实验测量结果相关联.
结论:
- 间接温度计是监测SiC晶体管温度的可行方法.
- 了解案例-死亡温度差异是防止损坏的关键.
- 可以确定优化的操作点,以提高设备可靠性.
相关概念视频
Equipments Used to Measure Body Temperature
977
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
977
Diode: Forward bias
912
In semiconductor devices, diodes play a crucial role in directing current flow, and its operation is primarily categorized into forward bias and reverse bias. A diode is said to be forward-biased when its p-type region is connected to the positive terminal of a battery and its n-type region is linked to the negative terminal. This configuration reduces the potential barrier within the diode, allowing current to flow easily from the p to the n-type region.
The behavior of a diode in forward bias...
The behavior of a diode in forward bias...
912
Assessing Body Temperature - Temporal Artery
529
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
529
Assessing Body Temperature - Oral
730
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
730
Temperature Measurement Sites
1.6K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.6K
Small-signal Diode Model
751
In analyzing the behavior of diodes in circuits, the relationship between the current through a diode and the voltage across it is of particular interest, especially when considering the effect of a direct current (DC) bias voltage. When applied, this DC bias influences the diode's operating point, known as the Q point, around which the current-voltage (I-V) characteristic of the diode exhibits exponential behavior. Introducing a small, time-varying signal on top of this bias aids in...
751