在插入电极中模拟和分析极化特征,考虑电荷转移和接触电阻
Kingo Ariyoshi1, Yuma Nagashima1
1Department of Chemistry and Bioengineering, Graduate School of Engineering, Osaka Metropolitan University, 3-3-138 Sugimoto, Sumiyoshi, Osaka 558-8585, Japan. ariyoshi@omu.ac.jp.
概括
接触电阻 (R_cont) 显著影响氧化 (LAMO) 电极极化. 降低R_cont是提高电极功率能力的关键,特别是在低温和高频率下.
科学领域:
- 电化学 电化学 电化学
- 材料科学 材料科学 材料科学
- 固态电池是一种固态电池.
背景情况:
- 在Li[Li 0.1Al0.1Mn1.8]O 4 (LAMO) 中的电极极化是由电荷转移电阻 (R ct) 和接触电阻 (R cont) 控制的.
- 了解这些电阻对于优化储能应用中的LAMO电极性能至关重要.
研究的目的:
- 为了研究R ct和R cont对LAMO电极极化行为的影响.
- 开发一种新的极化方程,描述不同极化模式之间的过渡.
- 确定R ct和R cont对于提高电极功率能力的相对重要性.
主要方法:
- 对称的LAMO/LAMO电池的制造和测试.
- 在不同条件下 (温度,频率) 分析极化曲线.
- 开发一个相当的电路模型来描述极化现象.
主要成果:
- 极化曲线从指数 (如图表) 过渡到线性 (如欧姆定律),因为R ct相对于R cont而下降.
- 这种转变在较低的温度和更高的频率下更加明显.
- 一个新的极化方程准确地模拟了观察到的实验行为.
结论:
- 降低接触电阻 (R cont) 比降低电荷传输电阻 (R ct) 更为提高LAMO电极功率能力至关重要.
- 开发的极化方程为预测和理解电极行为提供了有价值的工具.
- 优化电极-电解质接口以最大限度地减少R是未来电池开发的关键策略.
相关概念视频
Potential Due to a Polarized Object
369
A neutral atom consists of a positively charged nucleus surrounded by a negatively charged electron cloud. When placed in an external electric field, the external electric force pulls the electrons and nucleus apart, opposite to the intrinsic attraction between the nucleus and the electrons. The opposing forces balance each other with a slight shift between the center of masses of the nucleus and the electron cloud, resulting in a polarized atom. On the other hand, a few molecules, like water,...
369
Dielectric Polarization in a Capacitor
4.6K
The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
4.6K
Electrogravimetric Analysis: Overview
208
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
208
Induced Electric Dipoles
4.2K
A permanent electric dipole orients itself along an external electric field. This rotation can be quantified by defining the potential energy because the external torque does work in rotating it. Then, the potential energy is minimum at the parallel configuration and maximum at the antiparallel configuration. While the former is a stable equilibrium, the latter is an unstable equilibrium.
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
4.2K
Susceptibility, Permittivity and Dielectric Constant
1.4K
When placed in an external electric field, a dielectric material gets polarized. The charge density in the dielectric material is given by the sum of the bound and free charge densities, while the total charge density can also be written in terms of the total electric field. The bound charge density can be measured in terms of polarization, leading to the relationship between electric displacement and polarization.
1.4K
Controlled-Potential Coulometry: Electrolytic Methods
145
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
145