轴承的剩余使用寿命预测基于卷积注意网络和增强型变压器
Ning Sun1, Jiahui Tang2, Xiaoling Ye2
1School of Automation, Wuxi University, Wuxi, 214105, China.
Heliyon
|October 17, 2024
概括
本研究引入了MDSCT模型,用于使用原始振动数据准确预测滚动轴承的剩余使用寿命 (RUL). 该模型在预测轴承健康方面表现出卓越的性能和稳定性.
科学领域:
- 机械工程 机械工程
- 人工智能的人工智能
- 信号处理 信号处理
背景情况:
- 滚动轴承对于工业机械至关重要.
- 预测它们的剩余使用寿命 (RUL) 对于维护和防止故障至关重要.
- 现有的方法往往需要广泛的先验知识或复杂的功能工程.
研究的目的:
- 提出一种全新的端到端模型,MDSCT,用于高效和准确的轴承RUL预测.
- 直接利用原始振动信号,最大限度地减少对先前知识的依赖.
- 增强模型捕获复杂信号特征和非线性关系的能力.
主要方法:
- 开发了一个MDSCT模型,其中包括一个MDSC注意力模块,并行深度可分离的卷积和一个高效的注意力机制.
- 集成了一个PPSformer (Patch-embedding和Probesparse自我注意力变压器编码器) 用于本地和全球特征提取.
- 引入了一个改进的自适应激活功能,AdaptH_Swish,用于模拟非线性.
- 使用PHM2012和XJTU-SY数据集通过废除和比较实验验证实模型.
主要成果:
- 该MDSCT模型有效地从退化的轴承信号中提取局部微妙和全球依赖特征.
- 实验结果证实了模型的结构设计效率和合理性.
- 在标准数据集上,MDSCT在三个关键评估指标上显著优于现有方法.
结论:
- MDSCT模型为轴承RUL预测提供了一个强大的和可通用的解决方案.
- 拟议的架构和自适应激活功能提高了预测准确性和效率.
- 这种方法减少了对领域专业知识和在轴承预测中广泛预处理的需求.
更多相关视频
相关概念视频
Energy Losses in Transformers
839
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
839
Types Of Transformers
951
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
951
Transformers with Off-Nominal Turns Ratios
141
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
141
Three-Winding Transformers
209
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
209
Transformers in Distribution System
99
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
99
The Ideal Transformer
358
In single-phase two-winding transformers, two windings are coiled around a magnetic core characterized by cross-sectional area A and magnetic permeability μ. A phasor current i1 enters the left winding while i2 exits the right winding, establishing the fundamental working of the transformer through electromagnetic principles.
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
358