开发和应用双同位素标记方法,以提高在尿样中的兴奋剂的检测和定量,使用高分辨率质谱法
Yang Wang1, Wanli Li1, Xiaojun Deng2
1Shanghai Anti-Doping Laboratory, Shanghai University of Sport, Shanghai, 200438, China.
Analytical and bioanalytical chemistry
|October 25, 2024
概括
在反兴奋剂中,精确量化兴奋剂药物至关重要. 一种新的双标签衍生方法提高了使用液体染色学高分辨率质谱法 (LC-HRMS) 检测具有挑战性的物质的检测精度.
科学领域:
- 分析化学 分析化学
- 法医科学 法医科学 法医科学
- 生物化学 生物化学
背景情况:
- 反兴奋剂分析要求精确的定量检测刺激物质.
- 液体色谱-高分辨率质谱 (LC-HRMS) 越来越多地用于刺激剂检测.
- 缺少同位素标记的内部标准阻碍了刺激剂分析的定量准确性.
研究的目的:
- 为兴奋剂物质,特别是那些含有氨基或基基的物质,开发一种可靠的定量方法.
- 解决分析低LC-MS反应的小分子,同位素和化合物的挑战.
- 克服因缺少同位素标记的内部标准所带来的局限性.
主要方法:
- 开发一种双标签衍生系统,用于刺激剂量化.
- 该方法应用于含有氨基或醇基的兴奋剂物质.
- 开发的定量方法的方法验证.
主要成果:
- 双标签衍生方法为刺激剂分析提供了一种新的方法.
- 该方法有效地解决了低分子量物质,异构体和LC-MS反应差的挑战.
- 在定量分析中缺少同位素标记的内部标准问题提出了一个解决方案.
结论:
- 开发的定量方法显示了改善兴奋剂检测在反兴奋剂方面的重大前景.
- 这种方法为分析难以检测的小分子和同位素提供了新的视角.
- 该方法在克服定量质谱学的当前局限性方面具有潜在的应用.
更多相关视频
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
14.6K
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
2.0K
相关概念视频
High-Performance Liquid Chromatography: Types of Detectors
494
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
494
High-Resolution Mass Spectrometry (HRMS)
1.3K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.3K
Mass Spectrometry: Complex Analysis
726
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
726