关于分布式加热系统的性能和潜力的研究,用于使用多能源资源的峰值剃须
Tianyang Zhang1, Bart Julien Dewancker1, Weijun Gao1
1Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, Japan.
Scientific reports
|October 25, 2024
概括
这项研究引入了用于寒冷地区的新型分布式加热峰值剃须系统 (DHPS),整合了清洁能源以减少40%的排放,并实现了3.5年的回报期.
科学领域:
- 能源系统工程 能源系统工程
- 整合可再生能源的整合.
- 热力工程是热力工程中的一个.
背景情况:
- 气候变化需要从化石燃料过渡到可再生能源.
- 严冬地区在需求高峰期间面临传统供暖系统的挑战.
- 热需求的波动需要创新的解决方案来实现稳定和高效的供暖.
研究的目的:
- 提出和评估一个新的分布式加热峰值剃须系统 (DHPS).
- 在二次网络中整合城市热量和清洁能源.
- 为了提高效率,在初级网络中降低回流水温度.
主要方法:
- 该DHPS集成了太阳能集热器,电热储 (ETST) 和吸收热 (AHP) 装置.
- 使用TRNSYS模拟来评估在各种峰值剃须条件下的系统性能.
- 在DHPS和传统的峰值剪切炉 (PCB) 之间进行了比较分析.
主要成果:
- 在最佳峰值剃须系数 (θ=0.5) 的情况下,DHPS实现了1.251的初级能量比 (PER).
- 与传统系统相比,燃烧排放量减少了大约40%.
- 该系统证明了3.5年的静态回报期 (PBP).
结论:
- 在寒冷的气候下,DHPS为峰值负载管理提供了灵活和高效的解决方案.
- 该系统确保完全利用清洁能源和废热,提高能源可持续性.
- 在特定的电价条件下,DHPS的运营成本与PCB可比.
相关概念视频
Secondary Distribution
81
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
81
Power Distribution in Three-phase and Single Phase Circuits
292
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
292
Maximum Power Flow and Line Loadability
95
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
95
Three-Phase Circuits
387
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
387
Heating and Cooling Curves
22.7K
When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
22.7K
Fast Decoupled and DC Powerflow
176
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
176