基于MLFTA-SMC的风力发电直流采集系统的可靠性评估方法
Xueyan Bai1, Yanfang Fan2, Junjie Hou1
1School of Electrical Engineering, Xinjiang University, Urumqi, 830000, China.
Scientific reports
|October 25, 2024
概括
本研究引入了一种新的方法,用于评估风力发电直流采集系统的可靠性,使用多级故障树分析和状态空间模型检查 (MLFTA-SMC). 拟议的方法提高了风电场运营的安全性和稳定性.
科学领域:
- 电气工程 电气工程
- 可再生能源系统可再生能源系统
- 系统可靠性 系统可靠性
背景情况:
- 风力发电直流收集系统对于风电场运行至关重要.
- 评估这些系统的可靠性对于稳定的能源发电至关重要.
- 现有的方法可能无法完全捕捉这些系统的复杂性.
研究的目的:
- 为风力发电直流收集系统提出一种新的可靠性评估方法.
- 提高风电场的安全性和稳定的运行.
- 为评估系统可靠性提供卓越的方法.
主要方法:
- 风力发电直流收集系统拓和关键设备的分析.
- 构建多级断层树模型用于事件重要性计算.
- 应用MLFTA-SMC方法进行可靠性评估.
主要成果:
- 拟议的MLFTA-SMC方法有效评估不同直流收集系统拓的可靠性.
- 通过故障树模型计算各种事件的综合重要性.
- 在一座100兆瓦的风电场上的模拟验证了该方法的有效性.
结论:
- MLFTA-SMC方法在风力发电直流采集系统可靠性评估方面表现出显著的有效性和优势.
- 这些发现支持风电场的运行安全性和稳定性得到改善.
- 这种方法为未来可再生能源系统的可靠性研究提供了坚实的框架.
相关概念视频
Wind Turbine Machine Models
108
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
108
Multimachine Stability
142
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
142
Distribution Reliability and Automation
105
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
105
Three-Phase Short Circuit—Unloaded Synchronous Machine
125
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
125
Power System Three-Phase Short Circuits
77
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
77
Load-frequency control
126
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
126