真空辅助单TM 提取挥发性有机化合物 (VOCs) 从热混合青中进行剖析
Stefano Dugheri1, Giovanni Cappelli1, Niccolò Fanfani1
1Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.
Molecules (Basel, Switzerland)
|October 26, 2024
概括
本研究使用MonoTrapTM Sorptive采样对热混合青的挥发性有机化合物 (VOC) 排放进行了表征. 在识别关键气味化合物方面,RGC18-TD涂层被证明是最有效的.
科学领域:
- 环境化学环境化学
- 分析化学 分析化学
背景情况:
- 热混合青 (HMA) 是挥发性有机化合物 (VOC) 排放的重要来源.
- 描述HMA的气味活性VOC对于环境和健康评估至关重要.
- 对于高效的VOC分析,需要新的取取样本方法.
研究的目的:
- 评估MonoTrapTM技术用于描述HMA的VOC排放配置文件.
- 为了确定导致HMA排放的关键气味活性化合物.
- 为了比较不同MonoTrapTM涂层和采样模式的性能.
主要方法:
- 采用了MonoTrapTM自动化热脱落 (TD) 的 Sorptive 采样.
- 使用气体染色学-质谱学/光谱学 (GC-MS/O) 来分析HMA的VOC.
- 采用化学测量分析来比较涂层性能并评估真空/非真空采样.
主要成果:
- 在HMA排放中确定了35种关键的气味活性挥发性化合物,主要是化物,酒精和.
- 在峰值区域和平衡时间方面,MonoTrapTM RGC18-TD表现出卓越的性能.
- 真空辅助采样显著提高了VOC的吸收,特别是对于高沸点化合物.
结论:
- MonoTrapTM技术,特别是RGC18-TD涂层,对于表征HMA VOC排放配置文件非常有效.
- 混合和石墨碳单体吸附剂显示出高吸附能力,特别是对极性化合物.
- 了解吸附剂物理特征和吸收率之间的关系是优化吸附采样的关键.
更多相关视频
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
3.7K
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
7.6K
相关概念视频
Volatilization
372
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
372
Atomic Absorption Spectroscopy: Atomization Methods
381
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
381
Sample Preparation for Analysis: Overview
192
Sample preparation is an essential step in the analytical process. It involves preparing a sample so that it can be analyzed accurately. The goal is to extract the analyte, the substance you want to measure, from the sample while removing any components that may interfere with the analysis. Sample preparation techniques vary depending on the physical state of the sample.
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
192
Atomic Absorption Spectroscopy: Lab
311
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
311
