对MCSEMEM的水下恒定高压直流切换技术的研究
Zhibin Ren1, Meng Wang1,2, Xianhu Luo3
1School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China.
Sensors (Basel, Switzerland)
|October 26, 2024
概括
本研究引入了用于海洋控制源电磁 (MCSEM) 发射器的新直流 (DC) 切换方案,取代了交流电 (AC) 以防止危险的失衡. 新型直流系统通过减少拖线缆电流和减轻燃烧风险来提高安全性.
科学领域:
- 海洋地质物理学 海洋地质物理学
- 电气工程 电气工程 电气工程
- 动力电子产品的动力电子.
背景情况:
- 海洋控制源电磁 (MCSEM) 发射器需要在海底附近的高电流.
- 在MCSEM系统中,三相交流传输可能会导致三相不平衡,导致过多的电流和拖线缆安全风险.
研究的目的:
- 为MCSEM发射器提出和分析一种新的水下恒定高压直流 (DC) 开关方案.
- 用直流传输代替传统的交流传输,以提高运行安全性和效率.
主要方法:
- 开发一个模拟模型来分析拟议的直流开关方案.
- 关键硬件组件的设计:一个直流开关逆变器单元,一个过器单元和一个下调整整单元.
- 使用绝缘门双极晶体管 (IGBT) 模块和正弦脉冲宽度调制 (SPWM) 进行直流转换为交流.
主要成果:
- 拟议的方案有效地将3000V直流输入转换为可调节的48.3-73.4V直流输出.
- 在拖线缆上的电流得到了显著的减少.
- 从根本上避免三相失衡和交流电感应损失.
结论:
- 开发的直流开关方案在MCSEM运行中提供了一个更安全的替代方案,而不是AC传输.
- 这项技术有潜力减少拖线缆燃烧事件,并提高MCSEM系统的整体安全性.
相关概念视频
Preparation of Samples for Electron Microscopy
5.4K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.4K
MOSFET: Enhancement Mode
298
Enhancement-mode MOSFETs are pivotal components in electronics, distinguished by their capacity to act as highly efficient switches. They are part of the larger family of metal-oxide Semiconductor Field-Effect Transistors (MOSFETs). They are available in two types: p-channel and n-channel, each tailored to specific polarity operations.
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
298
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
DC Battery
758
A conductor needs to be a component of a path that creates a closed loop or full circuit to have a continuous current flowing through it. A current starts to flow if an electric field is created inside an isolated conductor that is not part of a full circuit. The conductor quickly develops a net positive charge at one end and a net negative charge at the other. These charges generate an electric field opposite the direction of the applied electric field, which reduces the current. Eventually,...
758