一项多中心研究比较了在没有工作通道的柔性内镜上的细菌减少在UV-C光消毒与标准内镜清洗器消毒之间:一个随机对照试验
Yana Halmans1,2, D J Wellenstein3, M Romijn3
1Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Center Nijmegen, P/O Box 9101, Nijmegen, The Netherlands. yana.halmans@radboudumc.nl.
Antimicrobial resistance and infection control
|October 27, 2024
概括
紫外线C (UV-C) 光消毒有效地减少了在没有工作通道的柔性内镜上形成殖民地的单位 (CFU). 这种UV-C方法在减少微生物污染方面被证明比标准的内镜清洗器消毒器 (EWD) 更有效.
科学领域:
- 微生物学 微生物学
- 传染性疾病 传染性疾病
- 医疗器械 医疗器械
背景情况:
- 没有工作通道的柔性内镜 (FEs) 需要彻底重新处理,以防止患者的交叉污染.
- 使用内镜清洗器消毒器 (EWD) 的当前再处理是耗时的.
- 紫外线C (UV-C) 光提供了一个可能更快的消毒替代方案.
研究的目的:
- 为了比较UV-C光消毒与没有工作通道的FE的EWD再处理的有效性.
- 评估微生物污染的减少,以殖民地形成单位 (CFU) 衡量.
主要方法:
- 从三个荷兰医院收集了没有工作通道的灵活内镜 (FEs).
- 进行手动预清洗,然后进行微生物培养.
- 经过随机分配,FE通过UV-C光或EWD进行消毒,并采用消毒后的培养物.
主要成果:
- 在消毒后,81.6%的UV-C处理的FE显示0 CFU,而用EWD处理的FE则为71.4% (p < 0.01).
- 紫外线-C光消毒显示,实现0 CFU的统计显著增加 (OR 1.83,95% CI 1.19-2.79).
- 有效性取决于参与的医院和FE类型.
结论:
- 在没有工作通道的柔性内镜上,UV-C光消毒在减少CFU方面比EWD更有效.
- 紫外线为这些医疗器械提供了一个有前途的替代消毒方法.
相关概念视频
Cleaning, Sterilization, and Disinfection
6.6K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
6.6K
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
2
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
2
Methods of Sterilization II: Chemical Methods
6.2K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
6.2K
Hand hygiene
3.1K
Asepsis is the practice of preventing or breaking the chain of infection. The nurse employs aseptic techniques to prevent the spread of microorganisms and reduce the risk of diseases. Hand hygiene is the cornerstone of aseptic techniques and is classified into medical and surgical asepsis. Medical asepsis includes hand hygiene and the use of gloves. Surgical asepsis, or the sterile technique, refers to practices that render and keep objects and areas free of microorganisms.
Hand washing...
Hand washing...
3.1K
Methods of Sterilization I: Physical Methods
19.6K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
19.6K
Methods for Controlling Microbial Growth
3
Microbial growth control refers to various methods employed to inhibit, reduce, or eliminate microorganisms to ensure safety and hygiene across different settings. These methods are categorized based on the target environment and the level of microbial control required.Biocides are versatile agents designed to control microorganisms by either inhibiting their growth or outright killing them. These agents work through various physical, chemical, mechanical, or biological mechanisms. The...
3