混合拉曼和部分波谱显微镜用于表征组织中的分子和结构变化
Elena Kriukova1,2, Mikhail Mazurenka1,2, Sabrina Marcazzan1,2
1Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine and Health, Technical University of Munich, Munich, Germany.
Journal of biophotonics
|October 27, 2024
概括
这项研究引入了混合拉曼光谱 (RS) 和部分波谱 (PWS) 显微镜. 这种综合方法增强了分子和结构组织变化的分类,改善了早期癌症诊断.
科学领域:
- 生物医学光学 生物医学光学
- 频谱学是一种光谱学.
- 分子成像学分子成像学
背景情况:
- 鉴定分子和结构组织变化的特征对于疾病诊断至关重要.
- 现有的光谱方法在全面分析组织变化方面可能存在局限性.
- 综合方法可以为组织分析提供协同效益.
研究的目的:
- 开发和验证混合拉曼光谱 (RS) 和部分波谱 (PWS) 显微镜.
- 评估系统在特征分子和结构组织变化的表现.
- 为了证明混合模式的增强诊断能力.
主要方法:
- 构建了一个新的混合显微镜,集成RS和PWS.
- 使用表面粗度标准 (PWS) 和晶标准 (RS) 验证了系统性能.
- 该系统在小鼠的胃和肠组织上进行了测试,包括瘤原生模型.
主要成果:
- 混合系统证明了胃和肠组织的更好的分类,将R2从0.892增加到0.964.
- PWS信息显著提高了RS数据分类的准确性.
- 该系统成功地从瘤原生小鼠模型中检测到肠道组织的变化.
结论:
- 混合RS-PWS显微镜有效地表征分子和结构组织变化.
- 将PWS形态特征与RS分子指纹结合起来,可以改善组织分类.
- 这种混合模式对推进致癌研究和早期癌症诊断具有前途.
相关概念视频
Raman Spectroscopy: Overview
315
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
315
Raman Spectroscopy Instrumentation: Overview
297
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
297
Super-resolution Fluorescence Microscopy
6.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.9K