相关实验视频
Updated: Jun 9, 2025

09:41
Blast Quantification Using Hopkinson Pressure Bars
Published on: July 5, 2016
9.0K
接触爆炸对超高性能钢筋混凝土板的影响:实验研究和维度分析
Wei Zhang1,2, Jize Mao1, Bukui Zhou3
1College of Aerospace and Civil Engineering, Harbin Engineering University, Harbin, 150001, China.
Scientific reports
|October 28, 2024
概括
超高性能混凝土板 (UHPCS) 与普通钢筋混凝土板 (NRCS) 相比,具有更高的抗爆性能. 超高压电压系统需要更大的爆炸弹来达到破裂模式,如分离和穿孔.
科学领域:
- 土木工程 土木工程是指土木工程.
- 材料科学 材料科学 材料科学
- 保护工程 保护工程
背景情况:
- 超高性能混凝土 (UHPC) 越来越多地用于保护工程.
- 对UHPC的有限研究阻碍了防爆结构设计.
研究的目的:
- 为了研究UHPC板块 (UHPCS) 的抗冲压性能.
- 为了比较UHPCS与普通钢筋混凝土板 (NRCS) 的抗爆性能.
- 开发UHPC板块故障值的预测模型.
主要方法:
- 对UHPCS和NRCS进行了接触式爆炸测试.
- 分析了故障模式 (分裂,穿孔) 和损坏水平.
- 标尺板厚度和电荷重量是关键参数.
主要成果:
- UHPCS显示出明显高于NRCS的爆炸阻力.
- 与NRCS (1.0-2.2公斤) 相比,UHPCS需要更大的爆炸弹 (1.6-5.0公斤) 来应对故障.
- 在UHPCS中,破坏指标,如石坑大小,裂大小和裂模式显著减少.
结论:
- 在结构应用中,UHPC提供了卓越的爆炸减轻能力.
- 提出了UHPCS的裂纹和穿孔值的预测公式.
- 开发并验证了UHPCS中火山口和裂尺寸的简单估计方法.
相关概念视频
Impact Strength of Concrete
178
Impact strength in concrete is a critical measure that reflects the material's capability to endure the forces applied during pile driving and when supporting machinery foundations that experience impulsive loads. It is also essential when handling precast concrete components to prevent accidental damage. The impact strength is assessed by observing the concrete's resistance to repeated impacts and energy absorption capacity. A key indicator of significant damage to concrete is when it...
178
Abrasion Resistance of Concrete
107
Abrasion resistance is an essential characteristic of concrete that determines its durability and longevity under various wear conditions. Concrete surfaces are vulnerable to different types of abrasion. For instance, surfaces may wear down due to the constant movement of vehicles or be eroded by solids carried in water, as seen in concrete canal linings. Specific tests are conducted to measure the abrasion resistance of concrete.
One such test is the revolving disc test, where three plates...
One such test is the revolving disc test, where three plates...
107
Behavior of Concrete Under Compressive Load
149
Concrete exhibits specific behaviors under different compressive loads. Understanding this is crucial for understanding its structural integrity. When concrete undergoes uniaxial compression, it tends to develop cracks that run parallel to the direction of the force. These parallel cracks stem from localized tensile stresses that occur perpendicular to the compression direction. Additionally, angled cracks may appear due to the formation of shear planes.
As the concrete specimen fractures under...
As the concrete specimen fractures under...
149
Microcracking in Concrete
104
Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
104
Effects of Creep
105
Creep in concrete, the gradual deformation under prolonged stress, significantly impacts the integrity of structures. For reinforced concrete beams, it can be a vital design consideration, as it increases deflection, sometimes necessitating additional design measures. In columns, especially slender ones under eccentric loads, creep can cause buckling, compromising their stability. However, creep can be beneficial in indeterminate structures by mitigating stresses that arise from shrinkage,...
105
Dynamic Modulus of Elasticity of Concrete
263
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
263