在食道状细胞癌中使用F-FDG PET-CT成像进行编程细胞死亡联体-1表达的非侵入性评估
Liming Miao1, Gang Xiao2, Wanqi Chen3
1School of Computer and Information Engineering, Hanshan Normal University, Chaozhou, 521041, Guangdong, China.
Scientific reports
|October 31, 2024
概括
这项研究开发了一种放射学模型,使用18F-FDG PET-CT扫描来非侵入性地评估食道癌中编程细胞死亡-1 (PD-L1) 表达. 该模型准确预测PD-L1水平,克服了活检的局限性.
科学领域:
- 在瘤学瘤学.
- 放射学 放射学是一门学科.
- 医疗成像医学成像
背景情况:
- 编程细胞死亡-1 (PD-L1) 对于癌症免疫疗法至关重要,但通过活检对其进行评估受到瘤异质性的限制.
- 活检提供PD-L1表达的局部视图,可能导致由于瘤内的空间和时间变化导致不准确的评估.
研究的目的:
- 开发和验证一种非侵入性放射学模型,用于评估食道状细胞癌中的PD-L1表达.
- 克服传统活检方法在捕捉PD-L1异质性的完整图像方面的局限性.
主要方法:
- 从18F-FDG PET-CT图像中提取的2,386个代谢瘤体积 (MTV) 特征的回顾性分析.
- 通过特征选开发放射学模型,识别七个独立因素,预测PD-L1表达.
- 使用培训和验证队伍验证模型.
主要成果:
- 放射学模型证明了PD-L1表达的强烈歧视,在训练队列中,在接收器操作特征曲线下的面积为0.888,在验证队列中为0.889.
- 决策曲线分析表明,放射学模型在0.669.9以下的值概率下,为预测PD-L1水平提供了更大的净收益.
- 临床影响曲线显示,在所有情况下,当值概率低于0.501.50时,损失/收益比小于1.
结论:
- 基于18F-FDG PET-CT成像的非侵入性放射学模型可以可靠地评估食道状细胞癌中的PD-L1表达.
- 与传统的活检方法相比,这种放射学方法提供了更全面,更准确的PD-L1状态评估.
- 该模型通过提供PD-L1表达的全面评估,在指导治疗决策方面显示出显著的临床实用性.
关键词:
18F-FDG PET-CT 皮革 皮革 皮革 皮革 皮革 皮革 皮革消化道癌 (ESOC) 是一种癌症.代谢性瘤的体积和体积.在PD-L1中.无线电学 (Radiomics) 是一种无线电学.更多相关视频
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
11.1K
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
17.9K
相关概念视频
Imaging Studies II: Positron Emission Tomography and Scintigraphy
89
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Fundamental Principles of PET
89
Positron Emission Tomography
4.0K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.0K