在阴茎长度测量中提高精度:基于证据的延伸阴茎长度指示器技术 (SPLINT) 的综合
Prabudh Goel1, Prativa Choudhury1, Komal Kaur Saroya1
1Department of Paediatric Surgery, All India Institute of Medical Sciences, New Delhi, India.
Journal of Indian Association of Pediatric Surgeons
|October 31, 2024
概括
这项研究提出了伸展阴茎长度指标技术 (SPLINT),用于准确测量儿童的阴茎长度. 通过标准化技术和对关键因素的考虑,SPLINT解决了测量变化.
科学领域:
- 儿科内分泌学 儿科内分泌学
- 人类解剖学 人类解剖学
- 医学测量技术 医学测量技术
背景情况:
- 阴茎长度 (PL) 测量在儿科内分泌学中至关重要.
- 现有的PL估计方法表现出显著的异质性.
- 缺乏标准化的技术使准确的评估变得复杂,特别是在伸展的阴茎长度 (SPL) 中.
研究的目的:
- 综合现有关于阴茎长度测量技术的证据.
- 提出一种标准化和可靠的技术来估计儿童的伸展阴茎长度 (SPL).
- 为了解决当前PL测量实践中观察到的异质性.
主要方法:
- 按照PRISMA指南进行的系统审查.
- 在PubMed,Embase和Scopus数据库中搜索关于人类PL测量技术 (1990年以后) 的研究.
- 鉴定和分析了来自145项研究 (90,895名参与者) 的影响PL测量的设备,技术,参与者特征和环境因素.
主要成果:
- 伸展的阴茎长度 (SPL) 是最常见的PL状态 (81.3%).
- 使用了多种不同的测量设备,包括规则 (54.68%) 和校准器 (9.7%).
- 影响SPL测量的关键因素被确定并集成到拟议的SPLINT技术中.
结论:
- 目前的阴茎长度 (PL) 估计技术存在显著的异质性.
- 拟议的伸展阴茎长度指标技术 (SPLINT) 提供了一个标准化的方法.
- SPLINT旨在提高儿童群体中SPL测量的准确性和一致性.
相关概念视频
Assessment of blood pressure in brachial artery(two-step method)
658
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
658
Electronic Distance Measuring Instruments
27
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
27
Distance Corrections
26
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
26
Distance Measurements by Taping
29
Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
29
Measurements of Strain
433
Strain quantifies the deformation of a material under force, typically measured as normal strain, which represents the change in length when compared with the original length. Electrical strain gauges are used for enhanced accuracy. These devices consist of a conductive wire mounted on a paper backing that adheres to the material's surface. These gauges operate on the piezoresistive effect, where the wire's electrical resistance changes in response to mechanical deformation. The strain...
433
Assessment of blood pressure in brachial artery(one-step method)
556
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
556