排水管道蒸汽入侵通道对子板压缩系统减轻性能的影响
Ning Ding1, Chenglin Hou2, Hongrui Li2
1School of Environment and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Journal of hazardous materials
|November 3, 2024
概括
当有排水管道等优选通道存在时,子板压缩 (SSD) 系统可能效率较低. 这些通道可以降低SSD性能,并可能增加室内空气蒸气入侵风险.
科学领域:
- 环境工程 环境工程
- 地质技术工程 地质技术工程
- 室内空气质量 室内空气质量
背景情况:
- 亚板压缩 (SSD) 是减轻蒸汽入侵 (VI) 的常见方法.
- 优选的VI路径,如下水道和陆地排水道,可能会损害SSD的有效性.
- 排水管道对SSD性能的影响需要进一步调查.
研究的目的:
- 评估SSD系统在减轻排水管道蒸汽入侵的有效性.
- 评估优先路径在各种条件下如何影响SSD性能.
- 为了确定与SSD在排水系统的存在下运行相关的潜在风险.
主要方法:
- 在有或没有排水管道的房屋中对SSD系统进行实地测试.
- 数字建模模模拟SSD性能在不同的场景涉及优先路径.
- 在自然条件和SSD条件下对亚板蒸气度进行比较分析.
主要成果:
- 发现子板排水系统抑制SSD性能,需要更高的流量和压缩.
- 与自然条件相比,SSD运行导致板下蒸汽度增加,引发了VI的关注.
- 模拟结果表明,优先路径的位置显著影响SSD系统的有效性.
结论:
- 亚板排水系统的存在可以显著损害SSD缓解蒸汽入侵的有效性.
- 标准的SSD操作可能会无意中增加蒸汽入侵的风险在存在优先路径.
- 优化SSD系统设计和操作需要考虑优先路径的影响和位置.
相关概念视频
Cavity Drainage and Flashings in Masonry walls
73
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
73
Multiple Pipe Systems
449
Multipipe systems consist of complex configurations of interconnected pipes designed to transport fluids efficiently across intricate networks. They are essential in engineering applications requiring precise control over flow distribution, pressure, and head loss. They are categorized into series, parallel, loop, and network configurations, each distinguished by unique flow characteristics and applications.
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
449
Single Pipe Systems
108
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
108
Design Example: Designing a Residential Plumbing System
398
The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
398
Shrinkage in Concrete
84
Shrinkage in concrete is primarily due to water loss from evaporation, hydration of cement, or carbonation, leading to a reduction in volume. The volumetric contraction results in volumetric strain in concrete. However, in practice, shrinkage is measured as linear strain, which is one-third of the volumetric strain.
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
84
Minor Losses in Pipes
664
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
664