Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Maxwell-Boltzmann Distribution: Problem Solving01:20

Maxwell-Boltzmann Distribution: Problem Solving

2.3K
Individual molecules in a gas move in random directions, but a gas containing numerous molecules has a predictable distribution of molecular speeds, which is known as the Maxwell-Boltzmann distribution, f(v).
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
2.3K
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

4.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.3K
Pharmacokinetic Models: Comparison and Selection Criterion01:26

Pharmacokinetic Models: Comparison and Selection Criterion

490
Physiological and compartmental models are valuable tools used in studying biological systems. These models rely on differential equations to maintain mass balance within the system, ensuring an accurate representation of the dynamic processes at play.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
490
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

427
Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
427
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

386
Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
386
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

394
A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
394

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Exposed: investigation of oxidation in selenium-tellurium evaporation materials and its effect on optoelectronic devices.

Journal of materials science. Materials in electronics·2026
Same author

Monte Carlo validation of signal-to-noise improvements in transmission imaging using correlated annihilation photon pairs.

Scientific reports·2026
Same author

Characterization of Thick Selenium Layers for Dual-Layer X-ray Imaging.

IEEE transactions on nuclear science·2026
Same author

Machine learning-assisted event classification in cadmium zinc telluride positron emission tomography detectors leveraging entanglement-informed angular correlations.

Scientific reports·2025
Same author

Optimizing parylene and photoconductor thickness in indirect conversion amorphous selenium detectors.

Proceedings of SPIE--the International Society for Optical Engineering·2025
Same author

A dual-layer direct/indirect flat panel detector for improved material decomposition: first studies of the indirect layer.

Proceedings of SPIE--the International Society for Optical Engineering·2025
Same journal

From Geometry to Intensity: A Coarse-to-Fine Pipeline for Unsupervised 3D Ultrasound Stitching.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

AVA: Automated Viewability Analysis for Ureteroscopic Intrarenal Surgery.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Kidney Endoscopy Video to Preoperative CT Alignment for Depth Estimation.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Deep learning‑based cell type prediction in lung tissue from brightfield histology using CODEX-derived labels.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Reconstructing physiological signals from fMRI across the adult lifespan.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Axially Swept Light-Sheet Microscopy using scattering and fluorescence contrast mechanisms.

Proceedings of SPIE--the International Society for Optical Engineering·2026
查看所有相关文章

相关实验视频

Updated: May 1, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.5K

对凸优化进行参数选择 对2面板PET系统进行时间校准.

Gregory Romanchek1,2, Shiva Abbaszadeh2

  • 1Dept. of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61891, USA.

Proceedings of SPIE--the International Society for Optical Engineering
|November 4, 2024
PubMed
概括
此摘要是机器生成的。

准确的巧合时间校准对于PET成像性能至关重要. 这项研究发现,由于参数选择问题或数据可变性,用于定时校准的普通最小平方 (OLS) 优化无法获得最佳结果.

关键词:
在这里,PET是PET.凸凸的优化优化参数选择参数选择时间校准时间校准时间分辨率时间分辨率

更多相关视频

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.3K
Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
08:02

Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals

Published on: November 15, 2024

521

相关实验视频

Last Updated: May 1, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.5K
Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.3K
Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
08:02

Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals

Published on: November 15, 2024

521

科学领域:

  • 医疗成像医学成像
  • 核物理 核物理 核物理

背景情况:

  • 巧合时间校准对于正子发射断层扫描 (PET) 成像是必不可少的.
  • 诸如电子,电缆长度和探测器物理等因素引入时间差异,增加随机率并降低性能.

研究的目的:

  • 为了研究用于凸优化的参数选择,使用普通最小平方 (OLS) 进行PET计时校准.
  • 为了评估所选参数与测量的巧合时间差异之间的相关性.

主要方法:

  • 测试了常见参数与实验巧合时间差异之间的相关性.
  • 评估了127个嵌套回归模型以优化平均平方误差 (MSE),贝叶斯信息标准 (BIC) 和半最大全宽度 (FWHM).

主要成果:

  • 在测试的模型中,FWHM性能大约提高了53%.
  • 定时分辨率从~304 ns提高到~160 ns,仍然远远偏离CZT探测器可实现的~10 ns FWHM.

结论:

  • 对于定时校准的OLS优化可能受到关键参数 (例如触发值,温度) 缺失或过度数据变化的限制.
  • 需要进一步的研究来确定最佳参数或替代校准方法,以提高PET计时分辨率.