多系统双离子对称电池的单个有机电极
Wenjun Li1, Huilin Ma1, Wu Tang2
1School of Materials and Energy, University of Electronic Science and Technology of China (UESTC), Chengdu, China.
Nature communications
|November 4, 2024
概括
一个新的有机双极电极,diquinoxalino[2,3-a:2:2
科学领域:
- 材料科学 材料科学 材料科学
- 电化学 电化学 电化学
- 有机电子 有机电子
背景情况:
- 有机电极为多功能离子存储提供了大的空隙空间.
- 设计稳定的有机材料对于先进的电池技术至关重要.
研究的目的:
- 设计和合成一个小分子有机双极电极,用于各种离子适应.
- 为了评估设计电极的电化学性能在,Na和K电池.
主要方法:
- 双诺素[2,3-a:2',3'-c]氨酸-2,6,10-三氨酸 (DQPZ-3PXZ) 的合成.
- 在基于Li/Na/K的半和双离子对称电池中进行电化学测试.
- 长期自行车稳定性的评估.
主要成果:
- DQPZ-3PXZ证明了五种不同的对抗离子 (Li+,Na+,K+,PF6-,FSI-) 的稳定托管.
- 在半电池中实现了高峰放电容量 (257/243/253 mAh g-1) 和能量密度 (609/530/572 Wh kg-1).
- 双离子电池在15,000个周期中表现出稳定的容量 (85/66/72 mAh g-1) 和能量密度 (59/50/52 Wh kg-1),并保持出色的容量.
结论:
- 设计的DQPZ-3PXZ是一种强大的有机双极电极,能够容纳多种离子类型.
- 这种材料对基于,纳和K的双离子电池具有显著的承诺,具有高性能和长寿命.
相关概念视频
Electrodes: Overview
1.2K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
1.2K
Potentiometry: Membrane Electrodes
466
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
466
Standard Electrode Potentials
43.5K
On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
43.5K
Batteries and Fuel Cells
27.0K
A battery is a galvanic cell that is used as a source of electrical power for specific applications. Modern batteries exist in a multitude of forms to accommodate various applications, from tiny button batteries such as those that power wristwatches to the very large batteries used to supply backup energy to municipal power grids. Some batteries are designed for single-use applications and cannot be recharged (primary cells), while others are based on conveniently reversible cell reactions that...
27.0K
Potentiometry: Types of Electrodes
533
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
533
Electrodeposition
606
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
606