调查离散技术对直流-直流增压转换器实时数字控制的影响:全面分析
Cağfer Yanarateş1, Zhongfu Zhou2, Aytaç Altan3
1Department of Electrical and Energy, Kelkit Aydın Doğan Vocational School, Gümüşhane University, Gümüşhane, 29600, Turkey.
Heliyon
|November 5, 2024
概括
这项研究比较了DC-DC增压转换器 (DBC) 的数字控制分密化方法. 它揭示了不同的技术如何影响DBC性能,稳定性和精度,以优化数字控制应用程序.
科学领域:
- 电气工程 电气工程
- 控制系统工程 控制系统工程
背景情况:
- 在可再生能源,电动汽车和电子产品中,DC-DC增压转换器 (DBC) 是至关重要的.
- 有效的数字控制对于优化DBC性能至关重要.
研究的目的:
- 进行对DBCs的离散化技术进行比较分析.
- 了解这些方法对控制系统行为,性能,稳定性和准确性的影响.
主要方法:
- 使用dSPACE实时接口 (RTI) 和硬件在循环中的 (HIL) 模拟进行验证.
- 执行控制算法的时间和频率域分析.
- 在dSPACE硬件上使用MATLAB/Simulink/Stateflow进行实验验证.
主要成果:
- 详细比较离谱化技术对DBC控制的影响.
- 评估性能,稳定性和准确性的权衡.
- 了解各种离散方法的优点和缺点.
结论:
- 对比分析为DBC中的数字控制应用提供了实际的好处.
- 根据知情选择离散技术可以提高DBC的性能和可靠性.
更多相关视频
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.3K
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
3.0K
相关概念视频
Fast Decoupled and DC Powerflow
176
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
176
Time-Domain Interpretation of PD Control
83
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
83
Feedback control systems
291
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
291
Bridge rectifier
531
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
531
Voltage Doubler Circuit
481
A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
481
Time and frequency -Domain Interpretation of PI Control
105
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
105