Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Electrodes: Overview01:17

Electrodes: Overview

1.2K
 Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
1.2K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Neurophysiological screening of individual variability for robust decoding in c-VEP-based BCI.

Imaging neuroscience (Cambridge, Mass.)·2026
Same author

Rough Auditory Alarms Mitigate Inattentional Deafness During Piloting-Like Task.

Human factors·2026
Same author

Near-invisible c-VEP-based passive BCI for mental workload monitoring.

Journal of neural engineering·2026
Same author

EEG-based assessment of long-term vigilance and lapses of attention using a user-centered frequency-tagging approach.

Journal of neural engineering·2025
Same author

The Contribution of Motion-Sensitive Brain Areas to Visual Speech Recognition.

The Journal of neuroscience : the official journal of the Society for Neuroscience·2024
Same author

Characterizing neurocognitive impairments in Parkinson's disease with mobile EEG when walking and stepping over obstacles.

Brain communications·2023

相关实验视频

Updated: Jun 8, 2025

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
06:34

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare

Published on: July 7, 2023

2.3K

利用纹理闪:迈向实用,视觉舒适和高性能干燥EEG代码-VEP BCI的飞跃.

Frédéric Dehais1,2, Kalou Cabrera Castillos1, Simon Ladouce3

  • 1Fédération ENAC ISAE-SUPAERO ONERA, Université de Toulouse, Toulouse, France.

Journal of neural engineering
|November 5, 2024
PubMed
概括

新的大脑-计算机接口 (BCI) 刺激,加博和里克尔补丁,减少眼睛疲劳,提高准确性. 这种视觉上不引人注目的方法提高了BCI的可访问性和效率,用于更广泛的应用.

关键词:
代码视觉唤起的潜在的代码.干燥的电脑脑电图.反应性大脑计算机接口 反应性大脑计算机接口基于纹理的刺激.视觉上的舒适度和视觉上的舒适度.

更多相关视频

High-density Electroencephalographic Acquisition in a Rodent Model Using Low-cost and Open-source Resources
12:39

High-density Electroencephalographic Acquisition in a Rodent Model Using Low-cost and Open-source Resources

Published on: November 26, 2016

15.8K
Stimulus-specific Cortical Visual Evoked Potential Morphological Patterns
09:42

Stimulus-specific Cortical Visual Evoked Potential Morphological Patterns

Published on: May 12, 2019

6.0K

相关实验视频

Last Updated: Jun 8, 2025

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
06:34

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare

Published on: July 7, 2023

2.3K
High-density Electroencephalographic Acquisition in a Rodent Model Using Low-cost and Open-source Resources
12:39

High-density Electroencephalographic Acquisition in a Rodent Model Using Low-cost and Open-source Resources

Published on: November 26, 2016

15.8K
Stimulus-specific Cortical Visual Evoked Potential Morphological Patterns
09:42

Stimulus-specific Cortical Visual Evoked Potential Morphological Patterns

Published on: May 12, 2019

6.0K

科学领域:

  • 神经科学是一个神经科学.
  • 生物医学工程 生物医学工程
  • 人与计算机的交互

背景情况:

  • 传统的反应性脑电脑接口 (BCI) 经常使用重复的视觉刺激,导致用户的不适和注意力减少.
  • 对于BCI应用,需要更舒适,更有效的视觉刺激.

研究的目的:

  • 引入用于增强反应 (StAR) 的新型视觉刺激,使用Gabor或Ricker补丁来优化神经反应并最大限度地减少外围分心.
  • 评估StAR刺激的性能和用户体验,与BCI范式中的传统普通闪相比.

主要方法:

  • 一个因数设计研究,24名参与者使用一个8个干电极EEG系统.
  • 参与者专注于以三种格式呈现的目标闪器:普通,基于Gabor和基于Ricker,在五类视觉唤起的潜能范式内.
  • 收集了主观评级和准确度指标,随后进行了在线实施以进行验证.

主要成果:

  • 加博和里克的刺激被评为视觉上舒适,在外围视觉中几乎看不见.
  • 使用Gabor (93.6%) 和Ricker (96.3%) 刺激仅使用88秒的校准数据,与普通闪 (65.6%) 相比,获得了更高的精度.
  • 在线实现显示了高精度 (97.5% cued, 94.3% asynchronous),平均解码时间为1.68s.

结论:

  • 加博尔和里克尔刺激为BCI应用提供了一个视觉不引人注目的和高度准确的替代方案.
  • 这些刺激与无凝,低密度EEG技术的整合提高了BCI的可访问性和效率.
  • 这项研究为扩大BCI应用超越实验室环境铺平了道路.