通过压力波形倾听心脏声音
Alessio Tamborini1, Morteza Gharib2
1Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA. atambori@caltech.edu.
一种新的手臂袖技术提取心脏声音,用于对左心室 (LV) 收缩性的非侵入性评估. 这种方法将声压波形特征与 LV 缩和腹缩功能相关联,改善心血管预后.
科学领域:
- 心血管生理学心血管生理学
- 生物医学工程 生物医学工程
- 诊断技术 诊断技术 诊断技术
背景情况:
- 目前的非侵入性心血管诊断通常依赖于外周压力,限制了全面的预后.
- 需要先进的非侵入性方法来评估心脏功能,特别是左心室收缩性.
研究的目的:
- 引入一种新的方法,使用标准的手臂袖子装置提取左侧心脏声音.
- 为了将提取的声音压力波形的特征与左心室 (LV) 收缩性的关键指标相关联.
主要方法:
- 使用一个带有增强信号分辨率的手臂袖装置来捕捉心血管系统的振动 (声压波形).
- 分析左心导管和手臂袖子测量的同时数据.
- 相关的特定波束 (WP1和WP2) 在声压波形中,具有LV收缩性参数 (LV dPdt-max和LV ndPdt-max).
主要成果:
- 在声压波形中识别了两个不同的波包 (WP1和WP2),与LV收缩和放松有关.
- WP1与LV同位体收缩有显著的相关性 (皮尔森-R = 0.65,p < 0.001).
- WP2与LV同位体放松有显著的相关性 (皮尔森-R = 0.55,p < 0.001).
结论:
- 臂袖声压波形为左心室与大动脉的动态合提供了宝贵的见解.
- 这种新的技术使左心室收缩率的非侵入性评估成为可能.
- 这些发现支持了这种方法在改善心血管预后方面的潜力.
更多相关视频
09:31Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
相关概念视频
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...