An Electrochemiluminescence-Based Assay for MeCP2 Protein Variants
Published on: May 22, 2020
27.2K
一个电化学发光装置用于可视化检测实际样本中的
Huaanzi Hu1, Cheng Wang2, Chen Qian3
1Department of Radiotherapy, the Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou Medical Center, Nanjing Medical University Changzhou 213003 P. R. China nxy@njmu.edu.cn.
RSC advances
|November 6, 2024
概括
一种新的电化学发光 (ECL) 装置能够高精度检测微量 (Pb2+). 视觉检测技术的进步具有通过识别污染来提高食品安全的巨大潜力.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 生物技术是生物技术.
背景情况:
- (Pb2+) 污染是由于其生物积累而造成的重大环境和健康问题.
- 现有的微量检测方法往往缺乏灵敏度或视觉输出.
- 开发快速,准确和可视检测的工具对于公共卫生和环境监测至关重要.
研究的目的:
- 开发一种新的电化学发光 (ECL) 装置,用于准确和可视化检测微量 (Pb2+).
- 使用金纳米粒子 (AuNPs) 和特异性体,创建一个敏感和特定的ECL探针.
- 为了证明该设备在复杂的现实世界样本中检测的能力.
主要方法:
- 通过将金纳米颗粒 (AuNPs) 修改为特异性体DNA,制造一个ECL探头.
- 将ECL探头集成到一氧化 (ITO) 基板上,形成一个特定于的阵列装置.
- 使用高响应的ECL成像系统可视化检测,实现9.8 pg L-1的超低检测极限 (LOD).
主要成果:
- 开发的ECL设备实现了Pb2+的9.8 pg L-1的超低检测极限 (LOD).
- 成功演示了可视化检测Pb2+的痕迹.
- 该装置显示出高特异性和精度,即使存在干扰离子和复杂的样本,如Lycium ruthenicum Murr.,Glycyrrhiza uralensis和湖水.
结论:
- 该研究介绍了一种基于ECL的先进技术,用于可视检测微量 (Pb2+).
- 开发的APTAMER功能化的AuNP-ECL探头和ITO阵列设备为检测提供了一个敏感和特定的平台.
- 这项技术通过快速和可视识别污染,显示了提高食品安全和环境监测的巨大潜力.
相关概念视频
Photoluminescence: Applications
379
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
379
High-Performance Liquid Chromatography: Types of Detectors
490
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
490
Electrogravimetric Analysis: Overview
208
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
208
Enzyme-Linked Immunosorbent Assay
12.4K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
12.4K
Effects of EDTA on End-Point Detection Methods
259
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
259
Atomic Emission Spectroscopy: Lab
149
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
149