一个空间划分多重复合自愈环网络的演示
Optics express
|November 14, 2024
概括
本研究提出了一种新的空间划分多重化自愈环保护方案,用于光网络. 它使用多核纤维和先进的开关技术,以最小的性能影响,实现高通量流量的强大保护.
科学领域:
- 光学网络的建立是因为光学网络.
- 电信工程 电信工程 电信工程
- 光子学是指光子学的使用方法.
背景情况:
- 高容量光学网络需要有弹性的保护机制.
- 空间分割多重复合 (SDM) 为增加光纤容量提供了一条道路.
- 环网架构很常见,但需要有效的保护策略.
研究的目的:
- 为了证明一个空间划分多重复合自愈环保护方案.
- 在实际设置中评估拟议方案的性能和可行性.
- 为了实现高吞吐量交通保护,损失最小.
主要方法:
- 使用4核弱合多核纤维实现3节点,2纤维环.
- 使用核心的多核放大器进行信号放大.
- 使用空间通道切换与8x8流量交换机和MEMS交换机进行保护.
- 集成光纤曲水龙头,同时监控所有核心的功率.
主要成果:
- 在保护路径上,每个网络元件的平均损失约为2dB.
- 成功证明了对超过120 Tb/s的线路侧交通的保护.
- 在C频段中使用偏振复合的16ary正方形振幅调制信号验证了该方案的有效性.
结论:
- 拟议的空间划分多重复合自愈合环保护方案对高容量光学网络有效.
- 这种方法可以实现最小的性能影响和高效的保护.
- 这项技术支持电信中对带宽的日益增长的需求.
相关概念视频
Long-patch Base Excision Repair
6.3K
Since the discovery of the two BER pathways, there has been a debate about how a cell chooses one pathway over the other and the factors determining this selection. Numerous in vitro experiments have pointed out multiple determinants for the sub-pathway selection. These are:
6.3K
Cable Subjected to a Distributed Load
1.4K
The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
1.4K
Network Function of a Circuit
1.1K
Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
1.1K
Zones of Protection
996
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
996