适合模型的加权最小平方作为主要组件分析的替代方法,用于分析能量分散式X射线光谱光谱图像
1Centre for Analysis and Synthesis, and NanoLund, Lund University, Box 124, 22100 Lund, Sweden.
概括
权重最小方形 (WLS) 在能量分散式X射线光谱 (EDS) 频谱成像中优于主要成分分析 (PCA). 与WLS (mfWLS) 方法相适应的模型准确地识别了组成梯度和包含,避免了PCA工件.
科学领域:
- 材料科学 材料科学 材料科学
- 分析化学 分析化学
- 频谱学是一种光谱学.
背景情况:
- 能量分散式X射线光谱 (EDS) 是材料表征的一个关键技术.
- 诸如主要组件分析 (PCA) 等多变量统计方法通常用于EDS数据分析.
- PCA可以引入人工物,特别是在较低的信号噪声比率下,并且缺乏与替代方法的公平比较.
研究的目的:
- 直接比较PCA与基于权重最小平方 (WLS) 的策略用于EDS频谱图像分析.
- 为了评估与PCA相比的WLS (mfWLS) 之后的模型装配的性能.
- 为了证明mfWLS在处理构成梯度,包含和工件方面的优势.
主要方法:
- 直接比较PCA与加权最小平方 (WLS) 方法.
- 应用模型拟合的总谱,其次是WLS (mfWLS).
- 在EDS频谱图像的四个代表性案例研究中进行评估.
主要成果:
- 在识别和描述组合梯度和包含方面,mfWLS始终优于PCA.
- 与PCA相比,mfWLS作为集群的预处理步骤被证明是优越的.
- 使用mfWLS方法可以避免与PCA相关的常见伪造和偏见.
结论:
- mfWLS为分析EDS频谱图像提供了PCA的优质替代方案.
- mfWLS方法为EDS数据提供了简单而准确的信号建模.
- 这种方法提高了使用电子显微镜进行材料表征的可靠性和准确性.
相关概念视频
Atomic Emission Spectroscopy: Overview
1.6K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.6K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
194
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
194
Atomic Emission Spectroscopy: Lab
149
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
149
¹H NMR: Interpreting Distorted and Overlapping Signals
1.0K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.0K
Mass Spectrometry: Overview
4.6K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
4.6K
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
802
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
802


