疏水处理及其与内部墙壁绝缘的应用
Toby Cambray1, Valentina Marincioni1, Hector Altamirano1
1UCL Institute for Environmental Design and Engineering, London, UK.
UCL open. Environment
|November 21, 2024
概括
石材墙壁的疏水处理可以减少湿度风险,但可能会阻碍干燥,如果绕过,可能会增加湿度. 一些处理方法可能会因冷解或盐结晶而造成表面损伤.
科学领域:
- 建筑科学 建筑科学
- 材料科学 是一种材料科学.
- 保护科学 保护科学
背景情况:
- 疏水处理用于减轻内部隔热的固体墙中的水分风险.
- 这些处理旨在减少菌生长和木材恶化等问题.
- 然而,如果受到损害,它们可以减缓干燥,并可能增加水分,并可能导致表面损坏.
研究的目的:
- 审查评估和预测表面损伤风险的方法,这些风险与石头上的疏水处理有关.
- 评估当前风险评估技术的有效性和局限性.
主要方法:
- 审查现有的关于水处理的文献.
- 对高热模拟能力和局限性的分析.
- 评估目前用于评估表面损伤风险的技术.
主要成果:
- 疏水处理可以减少水分含量,但可能会阻碍干燥,如果裂绕过处理,则导致水分增加.
- 表面损伤,主要来自结解和盐结晶,是某些处理的重大风险.
- 目前用于评估表面损伤风险的方法往往是简单的或不适用于现实世界的应用.
结论:
- 虽然有利于水分管理,但疏水处理需要仔细考虑干燥动态和潜在的表面损伤.
- 需要改进的实用方法来准确评估和预测这些处理引起的表面损伤风险.
- 进一步的研究是必不可少的,以平衡排湿的好处与材料降解的风险.
相关概念视频
Thermal Insulation in Masonry Walls
105
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
105
Cavity Drainage and Flashings in Masonry walls
73
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
73
Masonry Cavity Walls
795
Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction...
Maintaining a clean cavity during construction...
795
Masonry in Cold and Hot Weather Conditions
80
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
80
Masonry Curtain Walls
837
Masonry curtain walls employ brick or stone veneers supported by the building's structure to form an external cladding system that is both aesthetically appealing and functional. These walls are erected through two principal techniques, first by traditional layering of masonry units and second by using prefabricated panels. Traditional construction relies on steel shelf angles attached to the spandrel beam for support, with high-bond mortars ensuring secure attachment of masonry veneer...
837
Waterproofing and Anti-Bacterial Admixtures in Concrete
74
Concrete's susceptibility to water absorption is due to the capillary action within the pores of its hydrated cement paste. This action draws water in, creating the need for waterproofing admixtures to prevent such penetration. The efficacy of these admixtures is contingent upon the water pressure, with variations arising from different conditions such as rain, capillary rise, or hydrostatic pressure in structures intended to hold water.
Waterproofing admixtures render concrete hydrophobic,...
Waterproofing admixtures render concrete hydrophobic,...
74