Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

337
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
337
IR Spectrometers01:25

IR Spectrometers

1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Reply to "Comment on Liu et al. 'Discrepancies of Measured SAR between Traditional and Fast Measuring Systems' <i>Int. J. Environ. Res. Public Health</i>, 2020, <i>17</i>, 2111".

International journal of environmental research and public health·2020
Same author

Discrepancies of Measured SAR between Traditional and Fast Measuring Systems.

International journal of environmental research and public health·2020
Same author

A clinical evaluation of amlexanox oral adhesive pellicles in the treatment of recurrent aphthous stomatitis and comparison with amlexanox oral tablets: a randomized, placebo controlled, blinded, multicenter clinical trial.

Trials·2009
Same author

Long-term assessment of bladder and bowel dysfunction after radical hysterectomy.

Gynecologic oncology·2009
Same author

Oxidative stress contributes to silica nanoparticle-induced cytotoxicity in human embryonic kidney cells.

Toxicology in vitro : an international journal published in association with BIBRA·2009
Same author

A rapid and simple method for identifying Mycobacterium tuberculosis W-Beijing strains based on detection of a unique mutation in Rv0927c by PCR-SSCP.

Microbes and infection·2009

相关实验视频

Updated: Jun 6, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.6K

多频微波传感系统与频率选择方法用于粉碎煤度的多频微波传感系统.

Haoyu Tian1, Feng Gao1, Yuwei Meng1

  • 1Zhejiang Energy Digital Technology Co., Ltd., Hangzhou 310012, China.

Sensors (Basel, Switzerland)
|November 27, 2024
PubMed
概括

这项研究引入了一种新的多频微波传感系统,用于精确测量粉碎煤度 (PCC). 该系统使用主要组件分析 (PCA) 和直角匹配追求 (OMP) 进行最佳频率选择,提高燃煤发电厂的效率和安全性.

关键词:
选择频率的频率选择.微波传感器是一个微波传感器.直角匹配追逐 (OMP) 是指一个对应的方法.主要组成部分分析 (PCA)粉碎煤炭的度 粉碎煤炭的度交换机矩阵的交换机.

更多相关视频

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis
10:44

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis

Published on: February 12, 2019

9.9K
Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
10:34

Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow

Published on: April 24, 2014

10.7K

相关实验视频

Last Updated: Jun 6, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.6K
Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis
10:44

Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis

Published on: February 12, 2019

9.9K
Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
10:34

Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow

Published on: April 24, 2014

10.7K

科学领域:

  • 工程 工程师 工程师 工程师
  • 物理 物理学 物理
  • 材料科学 材料科学 材料科学

背景情况:

  • 精确的粉煤度 (PCC) 测量对于燃煤发电厂的效率和安全至关重要.
  • 传统的单频微波方法由于频率依赖的信号灵敏度存在局限性.

研究的目的:

  • 开发一种创新的多频微波传感系统,用于精确的PCC测量.
  • 通过利用频域信息来克服单频分析的局限性.

主要方法:

  • 实施了多频微波传感系统,可控制频率和信号路径.
  • 应用主要组件分析 (PCA) 用于插入丢失数据的维度减少.
  • 利用直角匹配追求 (OMP) 算法,根据自身向量贡献进行最佳频率选择.

主要成果:

  • 该系统有效地从高维的PCC数据中提取特征,并选择最佳频率.
  • 实地实验表明,PCC预测的最低平均绝对误差 (MAE) 为1.41%和0.85的相关系数 (0-0.5公斤/公斤).

结论:

  • 多频微波传感系统提供准确可靠的定量PCC预测.
  • 该系统能够迅速检测PCC波动,提高燃煤发电厂的运行安全和效率.