基于声音的工业设备无监督故障诊断,考虑到环境噪音
Jeong-Geun Lee1,2, Kwang Sik Kim3, Jang Hyun Lee4
1Department of Smart Digital Engineering, Inha University, Incheon 22212, Republic of Korea.
Sensors (Basel, Switzerland)
|November 27, 2024
概括
本研究引入了一种使用变异自编码器 (VAE) 和域适应神经网络 (DANN) 的新型机器故障诊断方法,以有效地诊断噪音环境中的故障,提高准确性和可靠性.
科学领域:
- 工程 工程师 工程师 工程师
- 人工智能的人工智能
- 信号处理 信号处理
背景情况:
- 环境噪音往往会影响使用声信号的机器故障诊断.
- 现有的方法在多样化或噪音条件下扎,性能下降.
研究的目的:
- 开发一种基于无监督学习的故障诊断方法,该方法对环境噪声具有稳定性.
- 为了提高机器故障诊断的准确性和可靠性,在具有挑战性的声学环境中.
主要方法:
- 使用变化自编码器 (VAE) 来学习正常的声学数据并通过重建错误识别故障.
- 应用域适应神经网络 (DANN) 弥合域差异,提高在杂的目标环境中的性能.
- 整合了Mel频率的cepstral系数,降噪,数据增强和指数加权移动平均值,用于功能增强和时间序列分析.
主要成果:
- VAE在时间序列数据上证明了有效的故障诊断,但在噪音条件下显示性能下降.
- 通过将源域模型调整为目标域,DANN在杂环境中显著提高了诊断性能.
- 联合VAE-DANN方法在不同噪声水平 (信号与噪声比率) 中保持了高的诊断准确性.
结论:
- 拟议的VAE和DANN组合为在环境噪音的情况下对机器故障诊断提供了强大的解决方案.
- 这种方法有效地克服了环境领域的转变,确保可靠的故障检测和分类.
- 这种方法对工业应用具有重大潜力,需要精确的基于声学的机器健康监测.
相关概念视频
Heart Sounds
1.8K
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
1.8K
Equipments Used To Measure Blood Pressure
834
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
834