心血管,感知和表现对单相对于多室血流限制袖口的反应
Nicholas Rolnick1,2,3, Victor S de Queiros4, Masoud Moghaddam5
1Department of Exercise Science and Recreation, CUNY Lehman College, New York, NY, United States.
Frontiers in sports and active living
|November 29, 2024
概括
血流限制 (BFR) 手的膀设计会影响运动反应. 单BFR (SC-BFR) 比多BFR (MC-BFR) 或没有BFR (N-BFR) 降低了运动性能和动脉硬度.
科学领域:
- 运动生理学 运动生理学
- 心血管生理学心血管生理学
- 生物医学工程 生物医学工程
背景情况:
- 血流限制 (BFR) 训练是提高炼效果的一种流行的方法.
- 不同的BFR袖口设计,如单腔 (SC-BFR) 和多腔 (MC-BFR),可能会引起不同的生理反应.
- 了解这些差异对于优化BFR培训协议至关重要.
研究的目的:
- 为了比较SC-BFR和MC-BFR对运动表现,心血管反应和感知力的影响.
- 调查不同BFR膀设计对抗力运动中急性生理适应失败的影响.
主要方法:
- 在27名健康参与者中,采用了随机交叉设计.
- 参与者在三个条件下进行了对失败的抵抗运动 (20%的1RM) (4组):SC-BFR,MC-BFR和没有BFR (N-BFR).
- 测量了心血管反应 (心骨脉冲波速) 和运动表现 (总重复次数).
主要成果:
- 与MC-BFR和N-BFR相比,SC-BFR显著减少了总重复次数.
- MC-BFR导致的重复次数比N-BFR少,但比SC-BFR多.
- 运动后SC-BFR减弱了动脉硬度 (脉冲波速度) 的增加,而MC-BFR和N-BFR显示出显著的升高.
- 与N-BFR相比,SC-BFR和MC-BFR条件中的不适度更高.
结论:
- BFR袖口的膀设计显著影响了急性炼反应.
- 与MC-BFR和N-BFR相比,SC-BFR施加了更大的性能下降,并改变了动脉硬反应.
- 无论是SC-BFR还是MC-BFR,都会导致相对于N-BFR的不适增加.
相关概念视频
Sites for measruring blood pressure
1.5K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.5K
Exercise and Cardiovascular Response
737
Exercise significantly impacts cardiovascular response, which is crucial for understanding patient health and designing effective treatment plans.
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
737
Autoregulation of Blood Flow
2.2K
Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
2.2K
Korotkoff Sounds
3.0K
Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
3.0K
Equipments Used To Measure Blood Pressure
834
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
834
Measurement of Blood Pressure
872
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
872