改进基于集体学习方法的拉曼测量的信号噪声比
Yufei Jia1, Yuning Gao1, Wenbin Xu2
1College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China.
Analytical and bioanalytical chemistry
|November 29, 2024
概括
本研究引入了一种集体学习方法,以增强生物样本中低信号噪声比 (SNR) 拉曼光谱. 该方法有效地恢复了详细的光谱信息,改善了数据质量,以便更快地进行分析.
科学领域:
- 分析化学 分析化学
- 频谱学是一种光谱学.
- 生物物理学的生物物理.
背景情况:
- 拉曼光谱分析生物化学成分,但由于信号弱和光,生物样本的信号噪声比 (SNR) 较低.
- 提高SNR对于准确的拉曼测量至关重要,特别是对生物标本的快速分析.
研究的目的:
- 开发和评估一个集体学习方法,用于恢复和否定低SNR的拉曼光谱.
- 评估拟议方法在提高生物样本拉曼测量的准确性和质量的有效性.
主要方法:
- 提出了一种集体学习算法,以拒绝和恢复低SNR拉曼光谱.
- 该方法使用来自真菌样本的986对拉曼测量得到了验证,将低SNR光谱与高SNR参考光谱进行比较.
主要成果:
- 整体学习方法显著提高了拉曼光谱的质量,产生了与高SNR参考光谱相似的结果.
- 获得的平均RMSE和MAE值分别为1.337 × 10−2和1.066 × 10−2,证明了高精度.
结论:
- 拟议的集体学习方法是数值增强拉曼光谱SNR的强大工具.
- 这种技术通过提高数据质量和减少测量时间,促进了从生物样本中快速获取拉曼值.
相关概念视频
Raman Spectroscopy Instrumentation: Overview
296
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
296
Raman Spectroscopy: Overview
309
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
309
NMR Spectrometers: Resolution and Error Correction
672
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
672