同时对木星极光离子圈和热层进行红外观测
Ruoyan Wang1, Tom S Stallard2, Henrik Melin2
1School of Physics and Astronomy University of Leicester Leicester UK.
概括
木星的北极光显示了来自多个来源的复杂加热,而不是单一的主导来源. 加热和冷却机制之间的相互作用,可能涉及局部热力学平衡,是理解极光能量学的关键.
科学领域:
- 行星科学 行星科学
- 空间物理 空间物理
- 大气科学 大气科学
背景情况:
- 木星的极光区域是动态的,受到各种能量输入的影响.
- 了解能量平衡对于理解木星大气过程至关重要.
研究的目的:
- 为了研究木星北方红外极光的能量来源和热结构.
- 为了确定木星的极光区域内的主导加热机制.
主要方法:
- 2017年6月2日使用Keck-NIRSPEC对H3+和H2排放的同时观测.
- 制作极地投影地图,详细说明H3+辐射,旋转温度,柱子密度和H2辐射.
主要成果:
- 发现极光区域内的温度变化约为1000 K.
- 没有一个单独的极光加热机制 (粒子沉,焦尔加热,离子阻力) 被确定为占主导地位.
- 观察到各种加热机制和H3+冷却恒温器效应之间的复杂相互作用.
结论:
- 木星的北极极光区域的能量来自于加热和冷却过程的复杂相互作用.
- 局部热力学平衡可能在热层加热中发挥重要作用.
- 据推测,主要的热源来自平流层以上的高度,但低于特定排放峰值.
相关概念视频
Infrared (IR) Spectroscopy: Overview
1.5K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
1.5K
IR Spectrometers
1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
284
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
284
IR Spectroscopy: Molecular Vibration Overview
1.9K
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
1.9K
Atomic Emission Spectroscopy: Instrumentation
338
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
338
Atomic Emission Spectroscopy: Interference
172
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
172


