基于Thioflavin T的光发光的糖醇/水溶液的快速冷却量化
Robert Tycko1, Jaekyun Jeon1,2
1Laboratory of Chemical Physics National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland 20892, United States.
The journal of physical chemistry. B
|December 3, 2024
概括
研究人员开发了一种新的方法来测量使用黄素T (ThT) 光发光的快速冷却速度. 该技术量化了在化学和生物分子研究中捕获短寿命中间体的关键冷却速度.
科学领域:
- 物理化学 物理化学
- 生物物理学的生物物理.
- 频谱学是一种光谱学.
背景情况:
- 快速冷却对于在化学和生物分子过程中捕获暂时中间体进行分析至关重要.
- 现有的结溶液的方法,比如喷到冷水浴中,缺乏精确的冷却速度测量.
- 模拟表明毫秒或亚毫秒的结时间,但实验验证是有限的.
研究的目的:
- 开发和演示一种用于量化溶液快速冷却速率的新方法.
- 通过实验测量快速冷技术实现的冷却速度.
- 将实验冷却速率与理论预测进行比较.
主要方法:
- 作为一个探测器,利用了蒂奥夫拉T (ThT) 的取决于温度的光发光.
- 在旋转的冷铜表面上结一喷射的ThT溶液 (糖醇/水).
- 分析了ThT光发光的图像,以确定冷却速率作为表面速度的函数.
主要成果:
- 冷却速度与旋转的铜表面速度 (0.456.2 m/s) 线性增加.
- 在表面速度>3.8 m/s时,达到低于100 μs (300260 K) 和700 μs (300230 K) 的冷却时间.
- 实验冷却速度与简单的导热模型有显著的差异.
结论:
- ThT光发光学方法提供了快速冷却速率的准确量化.
- 直接实验测量至关重要,因为简化的模型不能完全捕捉冷却动态.
- 这种技术可以更好地控制和理解时间解决研究的样本准备.
相关概念视频
Photoluminescence: Applications
374
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
374
Flame Photometry: Lab
213
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
213
Total Internal Reflection Fluorescence Microscopy
5.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.6K
Fluorescence and Phosphorescence: Instrumentation
540
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
540