电气热合系统的可靠性评估,考虑用户级综合能源系统故障后的操作模式
1College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China.
iScience
|December 5, 2024
概括
本研究引入了一种新的可靠性评估方法,用于集成能源系统 (UIES) 的未来能源系统. 该方法在故障期间准确评估电气热系统的可靠性指数,指导微型能源电网运行.
科学领域:
- 能源系统工程 能源系统工程
- 电力系统可靠性 电力系统可靠性
- 智能电网是一种智能电网.
背景情况:
- 用户级综合能源系统 (UIES) 的配电网络正在成为未来的能源系统.
- 传统的可靠性评估方法对于UIES是不够的,因为多能源合和岛屿能力.
研究的目的:
- 为配备UIES的电气热合系统开发一种新的可靠性评估方法.
- 为了解决评估复杂UIES操作的现有方法的局限性.
主要方法:
- 建议UIES的故障后运行模式,考虑多能源合作和联合岛屿运行.
- 建立了故障相关矩阵标准,以快速确定负载能源供应和UIES操作模式.
- 在可靠性评估框架内嵌入静态岛屿划分和动态负载减轻模型.
主要成果:
- 开发的方法准确计算复杂的UIES配置的可靠性指数.
- 在各种故障条件下验证了拟议方法的有效性和实用性.
- 该方法为微型能源电网运营提供了有价值的指导.
结论:
- 建议的可靠性评估方法对于具有UIES的现代配送网络是有效的.
- 该方法提高了在故障事件期间对能源系统的理解和管理.
- 这项研究支持未来微型能源网的可靠运行和发展.
相关概念视频
Power System Three-Phase Short Circuits
77
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
77
Reclosers and Fuses
84
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
84
Distribution Reliability and Automation
105
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
105
Multimachine Stability
141
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
141
Line Protection with Impedance Relays
66
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
66
Bus Impedance Matrix
105
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
105