电子束诱导的Mn氧化在TEM:洞察到Auger刺激的加热效应
Sung Bo Lee1, Jihye Kwon2, Hyoung Seop Kim3
1Department of Materials Science and Engineering and Research Institute of Advanced Materials, Seoul National University, Seoul 08826, Republic of Korea.
概括
电子束辐射会导致阿尔法 (α-Mn) 中的显著加热和MnO形成. 激发激发,而不是喷射,驱动这种氧化,导致微观结构变化.
科学领域:
- 材料科学 材料科学 材料科学
- 表面科学是一门学科.
- 电子显微镜电子显微镜
背景情况:
- 电子束辐射诱导材料的微观结构变化.
- 了解材料对电子束的反应对于显微镜和制造中的应用至关重要.
研究的目的:
- 在电子束辐射下研究α- (α-Mn) 的微观结构变化.
- 确定辐射过程中负责氧化的主要机制.
主要方法:
- 传输电子显微镜 (TEM) 用于微观结构分析.
- 用于热建模的有限元分析 (FEA).
- 对能量转移和位移能量的分析.
主要成果:
- 在TEM中观察到局部稀释和氧化 (MnO) 的形成.
- 降低的导热率表明有显著的局部加热.
- 联邦能源局确定了奥格尔激发是主导的加热机制,达到2300K.
- 发现冷却速度是超快的.
结论:
- 通过奥格尔激发的电子束诱导的加热是α-Mn中MnO形成的主要原因.
- 氧化并不是由于喷造成的缺陷形成,因为电子束能量低于Mn位移能量.
更多相关视频
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
1.7K
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
8.7K
相关概念视频
Transmission Electron Microscopy
5.4K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.4K
Scanning Electron Microscopy
4.1K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.1K
Overview of Electron Microscopy
8.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.5K
Preparation of Samples for Electron Microscopy
5.4K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.4K
Atomic Emission Spectroscopy: Overview
1.5K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.5K