揭开手术后在自由的动态:通过线性混合模型的超谱洞察力
Lukas Viktor Dirschedl1, Cosima Prahm1, Adrien Daigeler1
1Department of Hand, Plastic, Reconstructive and Burn Surgery, BG Klinik Tübingen, Eberhard Karls Universität Tübingen, Germany.
Journal of tissue viability
|December 6, 2024
概括
超光谱成像可以使用组织水指数 (TWI) 监测自由液积累. 低TWI可能表明片失效,有助于早期检测缺血-再输液损伤.
科学领域:
- 生物医学工程 生物医学工程
- 微手术 微手术是一种微手术.
- 医疗成像医学成像
背景情况:
- 术后监测自由片对于检测并发症至关重要.
- 和微循环变化是片生存能力的关键指标.
- 超光谱成像 (HSI) 为组织评估提供了一种非侵入性方法.
研究的目的:
- 通过使用HSI来研究手术后自由板中的液体积累.
- 分析胀对片活力和微循环的影响.
- 在关键的术后阶段检测微循环变化.
主要方法:
- 对41个自由片进行前性队列研究,在术后6天内进行监测.
- 使用HSI. 的组织水指数 (TWI) 的量化.
- 评估氧和度 (StO2),近红外 perfusion 指数 (NPI) 和组织血红蛋白指数 (THI).
- 激光多普勒流量计用于微血管血流.
- 用于TWI动态分析的线性混合模型.
主要成果:
- 可行的板显示TWI的线性增加 (+9.4%的POD6).
- 失败的门显示TWI下降 (比POD6下降33.6%).
- 男性的性别与较高的受体位点TWI相关.
- 在TWI和StO2,NPI,血流或THI之间没有发现显著的相关性.
结论:
- HSI是可行的床边监测,量化组织.
- 低TWI显示潜在的作为一个早期警告标志的片妥协.
- 这些发现可能有助于深入了解缺血-再输液损伤机制.
相关概念视频
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Expected Frequencies in Goodness-of-Fit Tests
A goodness-of-fit test is conducted to determine whether the observed frequency values are statistically similar to the frequencies expected for the dataset. Suppose the expected frequencies for a dataset are equal such as when predicting the frequency of any number appearing when casting a die. In that case, the expected frequency is the ratio of the total number of observations (n) to the number of categories (k).
Mass Spectrum: Interpretation
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Mass Spectrometry: Complex Analysis
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...