用于农业应用的印刷电位计传感器
Anju Toor1,2, Payton Goodrich2, Tyler L Anthony3
1School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States.
ACS omega
|December 9, 2024
概括
完全打印的氨传感器可以准确地测量各种土壤类型中的氨度. 这些传感器对于农业实时监测至关重要,有助于肥料管理和了解气损失.
科学领域:
- 农业科学 农业科学
- 环境科学 环境科学
- 传感器技术 传感器技术
背景情况:
- 氨 (NH4+) 对土壤营养物质的可用性和 (N) 损失至关重要.
- 对的实时监测对于有效的农业实践和了解N循环至关重要.
- 现有的传感器技术在不同的土壤环境中面临着挑战.
研究的目的:
- 在各种土壤类型中研究完全打印的氨离子选择性传感器的性能.
- 在不同的土壤湿度条件下评估传感器可靠性.
- 评估印刷传感器对实时土壤氨监测的潜力.
主要方法:
- 印刷的氨离子选择电极和Ag/AgCl参考电极的制造.
- 在水溶液和三种土壤类型 (沙子,泥炭,粘土) 中传感器的表征,在一系列氨度 (0.01-100毫米) 中.
- 在可变重力测量湿度下评估传感器响应,以模拟现场条件.
主要成果:
- 在水溶液中,传感器的灵敏度为53.6 ± 5.1 mV/十年.
- 在土壤中,测量灵敏度为55.7 ± 11mV/dec (沙子),57.5 ± 4.1mV/dec (粘土) 和43.7 ± 4mV/dec (泥炭).
- 在不同的土壤湿度水平下评估了传感器性能,表明了潜在的现场适用性.
结论:
- 完全打印的氨传感器在各种土壤类型和条件下显示出有希望的性能.
- 这些传感器为农业和环境应用中实时监测提供了可行的技术.
- 开发的传感器可以有助于改善肥料管理和更好地了解土壤气动态.
相关概念视频
Potentiometry: Membrane Electrodes
458
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
458
Potentiometry: Overview
1.5K
Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as...
1.5K
Key Elements for Plant Nutrition
18.6K
Like all living organisms, plants require organic and inorganic nutrients to survive, reproduce, grow and maintain homeostasis. To identify nutrients that are essential for plant functioning, researchers have leveraged a technique called hydroponics. In hydroponic culture systems, plants are grown—without soil—in water-based solutions containing nutrients. At least 17 nutrients have been identified as essential elements required by plants. Plants acquire these elements from the...
18.6K
Amperometry: Overview
446
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
446
Potentiometry: Types of Electrodes
526
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
526
Titration of a Weak Base with a Strong Acid
4.6K
The titration curve of a weak base like ammonia with a strong acid like hydrochloric acid is the mirror image of the titration curve of a weak acid with a strong base.
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
4.6K