五相耐故障永久磁铁电机的短路耐故障控制器,带有梯形后置电磁场
Qian Chen1, Yuhang Xia1, Jiabin Wang2
1School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China.
Fundamental research
|December 11, 2024
概括
一个新的控制策略可以在短路故障时减少五相电机的扭矩波动. 这种方法可以弥补故障引起的电流和相位损失效应,确保电机更顺地运行.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 电动机器 电动机器 电动机器
背景情况:
- 电机的短路故障需要移除相位,从而导致扭矩波动.
- 短路电流和相损失故障都会通过引入扭矩波动来降低电机性能.
研究的目的:
- 为五相耐故障常磁同步电机 (FTPMSM-TEMF) 引入一种新的耐故障控制策略.
- 在短路故障条件下,在FTPMSM-TEMF中实现低扭矩波纹运行.
主要方法:
- 建议采用耐故障控制策略,以补偿由短路电流和相位损失引起的扭矩波动.
- 该策略涉及注入一个脉冲元件,以抵消来自短路电流的扭矩波动.
- 对于故障条件,一个死流预测控制模型被扩展到跟踪容故障电流.
主要成果:
- 拟议的策略有效地弥补了由短路电流和相位损失引起的扭矩波动.
- 即使在故障条件下,也可以实现平滑的电机运行.
- 实验结果验证了耐故障控制策略的有效性和可行性.
结论:
- 开发的耐故障控制策略成功地在短路故障期间减轻了五相FTPMSM-TEMF电机中的扭矩波动.
- 该方法通过解决不利的故障影响,确保稳定和顺的电机运行.
- 这项研究展示了在故障场景下提高电机可靠性和性能的实用方法.
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
118
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
118
Power System Three-Phase Short Circuits
77
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
77
Bus Impedance Matrix
105
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
105
Control of Power Flow
252
There are several methods to control power flow in power systems:
252
Directional Relays
93
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
93
Time-Domain Interpretation of PD Control
83
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
83