通过低频 (THz) 拉曼光谱法进行快速多态差别的无校准方法
Magdalene W S Chong1,2, Martin R Ward1,3, Catriona McFarlan2
1EPSRC Future Continuous Manufacturing and Advanced Crystallisation Research Hub, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK. magdalene.chong@strath.ac.uk.
概括
应用于拉曼光谱的多变量曲线分辨率使得结晶过程的快速分析成为可能. 这种技术准确地量化了梅芬胺酸固体形式,与X射线衍射结果相匹配.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
- 制药科学 制药科学
背景情况:
- 结晶过程在制药制造中至关重要,需要强大的分析方法来监测.
- 非侵入性光谱技术为实时过程分析提供了优势.
- 固态形式的准确表征对于药物的有效性和稳定性至关重要.
研究的目的:
- 研究多变量曲线分辨率 (MCR) 对非侵入性拉曼光谱学的应用.
- 为了实现结晶过程的快速在线分析.
- 使用拉曼光谱量化不同固体形式的美芬胺酸.
主要方法:
- 使用多变量曲线分辨率 (MCR) 算法.
- 在结晶过程中获得了非侵入性的拉曼光谱.
- 分析了拉曼光谱,以识别和量化美胺酸多态 (I型,II型和二甲基胺溶酸盐).
主要成果:
- 证明了MCR在线拉曼光谱分析的成功应用.
- 实现了对美芬胺酸固体形式的准确量化.
- 在MCR-拉曼量化和离线X射线分析之间显示出出色的一致性.
结论:
- 多变量曲线分辨率是快速,非侵入性分析结晶的强大工具.
- 拉曼光谱与MCR相结合,为高通量选和过程监控提供了一种可行的方法.
- 开发的方法准确地描述了美胺酸的固体形式,支持药物开发.
相关概念视频
Raman Spectroscopy Instrumentation: Overview
296
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
296
Raman Spectroscopy: Overview
307
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
307
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
807
At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
807
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
1.1K
The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
1.1K