Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Elastic Strain Energy for Shearing Stresses01:20

Elastic Strain Energy for Shearing Stresses

667
As discussed in previous lessons, strain energy in a material is the energy stored when it is elastically deformed, a concept crucial in materials science and mechanical engineering. This energy results from the internal work done against the cohesive forces within the material. When a material undergoes shearing stress and corresponding shearing strain, the strain energy density, which is the energy stored per unit volume, is calculated. Within the elastic limit, where the stress is...
667

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Quantitative lung ultrasound spectroscopy: First comparison with gold standard computed tomography scan and standard lung ultrasound for diagnosis of pneumonia versus cardiogenic pulmonary edema.

The ultrasound journal·2026
Same author

Novel velocity model for the quantitative characterization of pleural sliding, in vivo multicenter clinical study on RF lung ultrasound data.

Computers in biology and medicine·2026
Same author

Towards reduced ultrasound localization microscopy acquisition times by uncoupling a bi-disperse microbubble population.

The ultrasound journal·2026
Same author

On the interception of the optimal imaging plane for pleural line scanning with automatic robot assisted lung ultrasound: An experimental study.

The ultrasound journal·2026
Same author

Terminology of pleural artifacts in ultrasound: a Tower of Babel.

Insights into imaging·2026
Same author

Corrigendum to "Fully automated quantitative lung ultrasound spectroscopy for the differential diagnosis of lung diseases: The first multicenter in-vivo clinical study" [Comput. Biol. Med. (200), 1 January 2026, 111365].

Computers in biology and medicine·2026

相关实验视频

Updated: Apr 28, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
07:21

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking

Published on: February 12, 2011

14.3K

缓解剪切波弹性图形中的高率需求,使用辐射基函数基础的重建:一个实验幻影研究.

Sajjad Afrakhteh1, Libertario Demi1

  • 1Department of Information Engineering and Computer Science, University of Trento, Italy.

Ultrasonics
|December 14, 2024
PubMed
概括
此摘要是机器生成的。

这项研究引入了一种新方法,用于降低剪波弹性图像 (SWE) 成像的率要求. 该技术成功地保持了精确的组织硬度测量,减少了数据采集时间.

关键词:
下降采样 下降采样框架速率 框架速率 框架速率插值 插值 插值 插值 插值 插值辐射基础函数的作用剪切波弹性图形学 剪切波弹性图形学超声波超声波是指超声波的使用.

更多相关视频

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

12.4K
Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology
11:11

Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology

Published on: June 10, 2014

11.5K

相关实验视频

Last Updated: Apr 28, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
07:21

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking

Published on: February 12, 2011

14.3K
Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

12.4K
Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology
11:11

Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology

Published on: June 10, 2014

11.5K

科学领域:

  • 医疗成像医学成像
  • 生物医学工程 生物医学工程
  • 超声波技术 超声波技术 超声波技术

背景情况:

  • 剪波弹性图 (SWE) 使用剪波速度量化组织刚性.
  • 传统上,高速率是准确的SWE成像所需要的.
  • 传统的超声波方法可以从SWE中获益,以提高组织特征.

研究的目的:

  • 为了减少SWE成像的高率要求.
  • 为了使SWE能够采集较低率的数据.
  • 在降低率下保持剪切波速度 (SWS) 估计的准确性.

主要方法:

  • 建议使用较低率的SWE成像方法.
  • 采用基于2D辐射基函数 (RBF) 的插值来进行时间上采样.
  • 重建了缺失的图像,以创建合成高率数据.

主要成果:

  • 实现了对SWE的率要求的4倍降低.
  • 保持剪波速度 (SWS),组速度和相位速度估计的误差为<3%.
  • 在SSIM>0.94和RMSE<0.37 m/s的2D-SWS地图中证明了高准确性,下采样因子高达4.

结论:

  • 拟议的插值技术有效地放松了SWE中的率要求.
  • 该方法在SWS估计中保持了很高的准确性,这对于组织表征至关重要.
  • 这一进步为更容易获得和更有效的SWE成像提供了一个有希望的方法.