液晶装载THz元材料中的异常共振频率转移
Eleni Perivolari1,2, Vassili A Fedotov3, Janusz Parka4
1Physics and Astronomy, University of Southampton, Highfield SO17 1BJ, Southampton, UK.
Nanophotonics (Berlin, Germany)
|December 16, 2024
概括
这项研究揭示了,由于电场不匹配,具有液晶的互补超材料模式具有不同的调范围. 观察到异常的频率转移,归因于液晶晶体.
科学领域:
- 超材料是什么?超材料是什么?
- 液晶是一种液晶.
- 太赫兹光谱法 太赫兹光谱法
背景情况:
- 具有液晶的元材料是可光谱调节的.
- 补充模式通常被认为具有相同的调范围.
研究的目的:
- 在互补的元材料模式中研究调范围的差异.
- 分析液晶对齐对太赫兹共振的影响.
- 探索混合超材料系统中的异常频率转移.
主要方法:
- 混合液晶加载元材料的制造.
- 太赫兹时域光谱测量共振.
- 分析电场-元材料相互作用和液晶对齐.
主要成果:
- 在互补的模式之间调灵敏度有显著差异.
- 确定了电场-元材料对齐不匹配的原因.
- 观察到的异常频率偏移超出了预测的限制.
结论:
- 液晶对齐显著影响元材料共振调.
- 阴性液晶中的定向光学非线性驱动异常转移.
- 混合元材料提供了新的可调节的太赫兹功能的功能.
相关概念视频
NMR Spectroscopy: Chemical Shift Overview
1.4K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
1.4K
Standing Waves in a Cavity
864
A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
864
Chemical Shift: Internal References and Solvent Effects
607
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
607


