降级混凝土孔的有效承载能力评估,使用部分均化
Tomasz Garbowski1, Tomasz Grzegorz Pawlak2, Anna Szymczak-Graczyk2
1Department of Biosystems Engineering, Poznan University of Life Sciences, Wojska Polskiego 50, 60-627 Poznan, Poland.
Materials (Basel, Switzerland)
|December 17, 2024
概括
本研究提出了一种快速的方法来评估退化的混凝土人井负载能力. 虽然修复恢复了显著的刚性,但它们并没有完全恢复原来的结构完整性.
科学领域:
- 土木工程 土木工程是指土木工程.
- 结构健康监测 结构健康监测
- 材料科学 材料科学 材料科学
背景情况:
- 混凝土人洞遭受严重的,不规则的恶化,损害结构完整性.
- 现有的修复方法,如聚尿素和聚氨泡,可以恢复形状,但不能完全承载能力.
- 详细的3D有限元分析对于工程评估来说,在计算上是不可避免的.
研究的目的:
- 开发一种实用和有效的方法来评估退化的混凝土人洞的承载能力.
- 评估当前修复策略在恢复结构性能方面的有效性.
- 为了使基础设施状况能够快速进行工程级别的评估.
主要方法:
- 表面扫描以创建损坏的人孔的详细和简化模型.
- 内部/外部聚尿素和可变厚度的聚氨泡用于修复的应用.
- 截面均化技术用于计算有效参数,用于简化建模.
主要成果:
- 拟议的断面均化方法允许使用最小的外元素进行快速工程级评估.
- 修复方法可以恢复高达76%的曲刚度在严重腐蚀的部分.
- 修复策略没有完全恢复人洞的原始承载能力.
结论:
- 已经建立了一种新的,计算效率高的方法来评估退化的人孔容量.
- 目前的维修技术可以部分恢复结构性能,强调需要进一步优化.
- 该研究为基础设施维护和管理决策提供了宝贵的工具.
相关概念视频
Slump Test
135
The slump test is a widely used method to measure the workability of concrete. It employs a 12-inch high truncated cone mold that tapers from eight inches at the base to four inches at the top. Before testing, the mold is securely attached to a flat base and dampened.
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
135
Segregation in Fresh Concrete
95
Segregation in fresh concrete is a phenomenon where the components of the concrete mix separate, leading to uneven distribution and compromised structural integrity. This separation typically occurs when concrete is subjected to excessive horizontal movement within forms, or when it is dropped from considerable heights or forced through narrow, winding paths. As a result, heavier coarse aggregate particles settle at the bottom, while lighter, finer materials such as cement and water rise to the...
95
Elasticity in Concrete
82
Upon subjecting concrete to moderate or high uniaxial compressive or tensile stresses, the strain response is non-linear relative to the stress applied. As the stress is removed, the resulting stress-strain curve deviates from the original path traced during loading, creating a hysteresis loop, indicative of the concrete's non-linear and non-elastic properties. Typically, a material's modulus of elasticity, which is a measure of the material's stiffness, is inferred from the linear...
82
Abrasion Resistance of Concrete
103
Abrasion resistance is an essential characteristic of concrete that determines its durability and longevity under various wear conditions. Concrete surfaces are vulnerable to different types of abrasion. For instance, surfaces may wear down due to the constant movement of vehicles or be eroded by solids carried in water, as seen in concrete canal linings. Specific tests are conducted to measure the abrasion resistance of concrete.
One such test is the revolving disc test, where three plates...
One such test is the revolving disc test, where three plates...
103
Shrinkage in Concrete
78
Shrinkage in concrete is primarily due to water loss from evaporation, hydration of cement, or carbonation, leading to a reduction in volume. The volumetric contraction results in volumetric strain in concrete. However, in practice, shrinkage is measured as linear strain, which is one-third of the volumetric strain.
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
78
Compacting Factor test
115
The compacting factor test is a method used to assess the workability of concrete. It is especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
115