屏蔽性能的新型模拟模型基于磁屏蔽的无热磁性属性
Yuzheng Ma1,2, Minxia Shi1,2,3, Leran Zhang1,2
1Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.
Materials (Basel, Switzerland)
|December 17, 2024
概括
这项研究引入了一种新模型,通过计算永久合金板的异性质来准确计算屏蔽房间的磁性屏蔽系数. 与以前的方法相比,改进的模型显著减少了计算错误.
科学领域:
- 材料科学 材料科学 材料科学
- 电磁主义 电磁主义
- 磁性屏蔽屏蔽是一种磁性屏蔽.
背景情况:
- 高性能常态合金板对于接近零磁场的环境至关重要.
- 传统的接会降低常态合金的磁性,因此常常会忽视异构性.
- 这些因素导致在评估磁屏蔽房间 (MSR) 性能时不可预测的错误.
研究的目的:
- 提出一个修改的模型来计算MSR的屏蔽系数 (SF).
- 为了将永久合金板的异性磁性特征纳入SF计算.
- 为了提高MSR性能评估的计算精度.
主要方法:
- 使用二维单片测试仪 (2D-SST) 测量永久合金板的异构磁性特性.
- 在不同的磁化状态和方向下开发了B和H信号的高精度测量系统.
- 开发了一个数学模型,根据测量和有限元模拟调整经验系数 (λ).
主要成果:
- 经验系数的比率与不同方向的磁透率的比率成反比例.
- 与有限元模拟相比,修改后的模型显著降低了平均平方误差 (MSE) 从49.97降至0.13.
- 在屏蔽因子计算的计算准确性方面取得了实质性的改进.
结论:
- 拟议的修改模型在SF计算中准确地考虑了永久合金板的异构性.
- 这种方法减轻了MSR设计中材料降解和异质性引入的错误.
- 改进后的模型为评估和设计磁屏蔽房间提供了更可靠的方法.
相关概念视频
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
831
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
831
Magnetic Susceptibility and Permeability
962
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
962
π Electron Effects on Chemical Shift: Overview
1.0K
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.0K
Potential Due to a Magnetized Object
261
Magnetic dipoles in magnetic materials are aligned when placed under an external magnetic field. For paramagnets and ferromagnets, dipole alignment occurs in the direction of the magnetic field. However, the dipoles align opposite to the field in the case of diamagnets. This state of magnetic polarization due to the external field is called magnetization. Magnetization is defined as the dipole moment per unit volume. It plays a similar role to polarization in electrostatics.
The vector...
The vector...
261
Magnetic Field Of A Current Loop
4.4K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
4.4K
Magnetic Damping
421
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
421