机械波传播在固化水泥基复合材料中的实验研究
Luboš Jakubka1, Libor Topolář1, Anna Nekorancová1
1Faculty of Civil Engineering, Brno University of Technology, Veveří 331/95, 602 00 Brno, Czech Republic.
Materials (Basel, Switzerland)
|December 17, 2024
概括
一种新的非破坏性超声波方法通过检测机械波变来有效监测水泥复合材料的硬化. 这种技术提供了高可变性和水化过程质量的明确指标.
科学领域:
- 材料科学 材料科学 材料科学
- 土木工程 土木工程是指土木工程.
- 非破坏性测试 不破坏性测试
背景情况:
- 基于水泥的复合材料在建筑中至关重要.
- 监测它们的凝固和硬化对于质量控制至关重要.
- 现有的方法可能缺乏精度或具有破坏性.
研究的目的:
- 引入和验证一种用于监测水泥复合材料硬化的新型测量程序.
- 为此目的研究通过脉冲超声波方法的使用.
- 评估该方法对细粒度水泥基复合材料的适用性,其水-水泥比率各不相同.
主要方法:
- 一个实验性研究利用通过脉冲超声波测量系统.
- 在水泥复合材料固化过程中监测机械波传播的变化.
- 分析振幅波形和主导频率的频谱.
主要成果:
- 在不同的水-水泥比率中观察到机械波浪参数的明显差异.
- 在机械波的振幅增加波形中记录了显著的变化.
- 频谱中的清晰频率线表明了水化过程的质量.
结论:
- 脉冲通道超声波方法是一种可行的,非破坏性的技术,用于监测细粒度水泥基材料.
- 该方法表现出高度的变化性,并为水化过程提供了洞察力.
- 这种超声波方法的潜在未来应用范围超出了水泥材料的范围.
相关概念视频
Strength of Cement
122
Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
122
Porosity in Cement Paste
116
The porosity of concrete is a measure of the void spaces within its structure. These spaces impact its strength and durability significantly. When water and cement interact, a chemical reaction called hydration creates a semi-solid paste. This paste includes combined water, making up approximately 23% of the cement's dry mass, and gel water, which fills minuscule voids known as gel pores, accounting for about 28% of the cement gel volume.
The balance of water to cement in the mix is...
The balance of water to cement in the mix is...
116
Soundness of Cement
143
The soundness of cement refers to the ability of cement paste to retain its volume after setting. Unsound cement can lead to expansion and structural damage due to the presence of free lime, magnesia, and calcium sulfate. Free lime hydrates very slowly, expanding and causing unsoundness, which is difficult to detect because it intercrystallizes with other compounds. Magnesia also reacts with water, forming crystals that can disrupt the cement's structure. Calcium sulfate can create...
143
Effects of Air-entrainment in Concrete
79
Air entrainment in concrete significantly enhances the material's durability, especially in environments subjected to freeze-thaw cycles. Introducing small air bubbles into the concrete mix acts as internal voids that accommodate the expansion of water when it freezes, thereby alleviating internal stress and preventing structural cracks. This function is crucial in climates with significant freezing and thawing, as it protects the concrete from repeated stresses that could lead to premature...
79
Effect of Sea Water on Concrete
171
Concrete exposed to seawater can undergo degradation like the dissolution of ettringite and gypsum, increasing the material's porosity and decreasing its strength. In contrast, the crystallization of salts within the concrete's pores can cause expansion, particularly above the waterline where evaporation occurs. Nonetheless, this expansion only happens when seawater, enabled by the concrete's permeability, manages to infiltrate the structure.
Concrete in areas between tide marks,...
Concrete in areas between tide marks,...
171
Dynamic Modulus of Elasticity of Concrete
254
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
254