使用电极从矿井水中提取,和铁的电凝
Muhammad Ghozali Harahap1, Muhammad Sonny Abfertiawan1, Mindriany Syafila1
1Water and Wastewater Engineering Research Group, Faculty of Civil and Environmental Engineering, Bandung Institute of Technology, Indonesia.
Heliyon
|December 17, 2024
概括
这项研究开发了一种电凝反应器 (EC) 来从矿水中去除重金属. 欧盟反应堆实现了高去除,和铁的效率,提供了一个可持续的解决方案.
科学领域:
- 环境工程 环境工程
- 水处理技术水处理技术
- 矿业减轻影响 矿业减轻影响
背景情况:
- 印度尼西亚的矿开采对经济产生了重大影响,但却以,和铁污染了水.
- 矿井水污染对水生生态系统和人类健康构成风险.
研究的目的:
- 开发一个电凝反应堆,从矿井水中去除,和铁.
- 通过改变电流密度和输入速率来优化EC反应器的性能.
主要方法:
- 使用了带有电极的连续电凝反应堆.
- 测试了不同的电流密度 (3.37810.135 mA/cm2) 和输入速率 (0.31 L/min).
- 分析了去除效率,电荷负载和雷诺兹数.
主要成果:
- 在最佳条件下 (6A电流,0.3L/分钟输入) 产生了86.89%的,99.51%的和80.61%的铁去除.
- 达到11.194F/m3的电荷负荷和39的雷诺兹数.
- 证明了EC技术对矿废水处理的有效性.
结论:
- 开发的EC反应堆有效地从矿水中去除关键重金属.
- 欧洲共同体技术显示出矿业废水可持续处理的巨大潜力.
- 进一步的研究可以为更广泛的环境应用改进EC工艺.
相关概念视频
Electrodeposition
597
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
597
Coagulation
266
Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
266
Precipitation and Co-precipitation
1.7K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.7K
Precipitation Gravimetry
5.3K
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
5.3K
Extraction: Advanced Methods
415
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
415
Electrogravimetric Analysis: Overview
202
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
202