对于飞机动力系统的低压电弧中电压和电流波形的数据集
Santiago Bogarra1, Manuel Moreno-Eguilaz2, Juan Antonio Ortega-Redondo2
1Department of Electrical Engineering, Universitat Politècnica de Catalunya, Campus of Terrassa, 08222, Terrassa, Spain.
Scientific data
|December 20, 2024
概括
这项研究引入了一个新的数据集,用于检测飞机电气系统中的平行弧故障. 这些数据有助于为电动飞机开发先进的电弧故障检测和识别方法.
科学领域:
- 电气工程 电气工程
- 航空航天工程 航空航天工程
- 材料科学 材料科学 材料科学
背景情况:
- 飞机的电气系统面临着平行弧故障的风险.
- 开发强大的电弧故障检测对于电动飞机的安全性和可靠性至关重要.
- 现有的数据集可能不能完全代表各种各样的飞机操作条件.
研究的目的:
- 提出一个全面的实验数据集,用于飞机电气系统的平行弧故障检测.
- 为在不同飞机相关压力下建模弧形行为提供资源.
- 为了促进先进的弧形故障识别算法的开发和验证.
主要方法:
- 在低压室中进行了960次实验,模拟了飞机环境.
- 在12个距离和10个压力条件下,在两个绝缘材料上使用了两个电极配置.
- 记录了每种实验条件的100万个时间,电流和电压信号样本.
主要成果:
- 创建了960个实验记录的数据集,捕捉了电弧现象.
- 该数据集包括在不同压力和材料条件下详细的电信号数据.
- 数据允许分析弧形行为和模式识别.
结论:
- 开发的数据集是推动飞机中弧形故障检测的宝贵资源.
- 它支持模拟弧形行为和改进弧形识别技术.
- 允许开发用于更多电动和全电动飞机的检测系统.
相关概念视频
Electrical Power
3.0K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.0K
Power System Three-Phase Short Circuits
77
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
77
Three-Phase Voltages
217
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
217
Electrical Current
5.6K
Electrical current is defined as the rate at which charge flows. When there is a large current present, such as that used to run a refrigerator, a large amount of charge moves through the wire in a small amount of time. If the current is small, such as that used to operate a handheld calculator, a small amount of charge moves through the circuit over a long period of time. The SI unit for current is the ampere (A), named for the French physicist André-Marie Ampère (1775–1836).
5.6K
Voltammograms: Overview
165
Voltammograms are current plots as a function of applied potential, offering insights into electrochemical systems. The shape of a voltammogram depends on how the current is measured and whether convection (heat transfer by fluid movement) is present or absent.
Shapes of Voltammograms
Shapes of Voltammograms
165
Three-Phase Short Circuit—Unloaded Synchronous Machine
118
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
118